Manufacturer : Meggitt (Vibro-Meter)
Product No. : 913-402-000-013/A1-E095-F2-G093
Product Type : Proximity Measuring System
913-402-000-012
Environment (A) : 1 = Standard
Extension cable length (E) : 095 = 9.5 m ±950 mm
Optional protection (F) : 2 = Flexible hose with FEP sheath, None Connector
Flexible hose length (G) : 093 = 9.3 m
Weight : 0.22 Kg
General
Transducer input requirements : High-frequency power source from an IQS900 signal conditioner
Environmental
Temperature ranges
Transducer : −40 to +180°C with drift <5% (operating).
+180 to +220°C with drift >5% (short-term survival).
Transducer and cable : −40 to +195°C if used in an Ex Zone
Cable, connector and optional
protection
: −40 to +200°C
Protection rating
(according to IEC 60529)
: The head of the proximity transducer (transducer tip and integral
cable) is rated IP68
Vibration
(according to IEC 60068-2-26)
: 5 g peak between 10 and 500 Hz
Shock acceleration
(according to IEC 60068-2-27)
: 15 g peak (half sine-wave, 11 ms duration)
Physical characteristics
Transducer construction : Wire coil Ø8 mm, Torlon (polyamide-imide) tip, encapsulated in
stainless steel body (AISI 316L) with high-temperature epoxy glue
Integral and extension cables : FEP covered 70 Ω coaxial cable, Ø3.6 mm
Connectors : Self-locking miniature coaxial connectors.
Note: When connecting, these should be hand-tightened until
locked.
Optional protection
Flexible stainless steel hose
(protection tube)
: The stainless steel hose provides additional mechanical protection
but is not leak-tight
FEP sheath
(extruded fluorinated ethylene
propylene)
: The FEP sheath provides resistance to almost all chemicals and low
permeability to liquids, gases and moisture. It is also flexible, low
friction and mechanically tough.
Weight : 200 g (0.44 lb) approx.
Mounting
Without DIN-rail mounting adaptor : Two M4 screws
KEY FEATURES AND BENEFITS
From the vibro-meter® product line
Non-contact measurement system based on
eddy-current principle
Ex certified versions for use in hazardous areas
(potentially explosive atmospheres)
Conforms to API 670 recommendations
1, 5 and 10 m systems
Temperature-compensated design
Voltage or current output with protection
against short circuits
Frequency response:
DC to 20 kHz (−3 dB)
Measurement range:
2 or 4 mm
Temperature range:
−40 to +180 °C
APPLICATIONS
Shaft relative vibration and gap/position
measurement chains for machinery
protection and/or condition monitoring
Ideal for use with VM600Mk2/VM600 and
VibroSmart® machinery monitoring systems
API 670 applications