Product Overview
When unplanned downtime from undetected vibration threatens rotating machinery, the Bently Nevada 9200-09-01-02-00 provides a reliable solution. This Two-Wire Velocity Seismoprobe Transducer is part of the industry-leading 9200 series, engineered for continuous vibration monitoring in harsh industrial environments. With factory warranty for 12 months and available new in original packing, this module delivers precise velocity measurements essential for predictive maintenance.
Technical Specifications
The Bently Nevada 9200-09-01-02-00 offers the following key parameters, ensuring accurate and repeatable performance:
| Parameter |
Value |
| Sensitivity |
20 mV/mm/s (500 mV/in/s), ±5% when properly terminated |
| Calibration Load |
10 kΩ Terminal A to B output |
| Sensitivity Temperature Coefficient |
0.2%/°C |
| Dynamic Operating Range |
2.54 mm (0.100 in) peak-to-peak maximum displacement |
| Velocity Range |
25 mm/s (1 in/s) at +22 °C, 100 Hz, 10 kΩ load |
| Coil Resistance |
1.25 kΩ ±5% |
| Locked Coil Inductance |
125 mH typical |
| Operating Temperature Range |
-29°C to +121°C (-20°F to +250°F) |
| Relative Humidity |
To 95% noncondensing; 100% non-submerged with integral cable |
| Height |
102 mm (4 in) typical |
| Diameter |
41 mm (1.6 in) typical |
| Weight |
300 grams (10.5 oz) typical |
The transducer mounts with a 1/4-28 UNF stud and offers a top-mount connector option, making it versatile for various field installations.
Industry Applications
Commonly deployed in oil and gas refineries, power generation plants, and heavy manufacturing facilities, the Bently Nevada 9200-09-01-02-00 monitors bearing and casing vibration on pumps, compressors, turbines, and fans. Its 15 Hz minimum operating frequency makes it ideal for low-speed machinery. For environments requiring high reliability, this transducer helps detect early signs of imbalance, misalignment, or bearing wear, preventing catastrophic failures.
Installation & Setup Guidance
To ensure accurate readings, mount the Bently Nevada 9200-09-01-02-00 with the correct orientation: the transducer can be rotated 0 ±180° from factory calibration angle. Use the provided 1/4-28 UNF stud for secure attachment to a flat, clean surface. Connect the two-wire output across pins A and B with a 10 kΩ termination load for proper operation. Avoid excessive cable strain and ensure the environment remains within -29°C to +121°C for reliable performance.
Selection Guide & Purchasing Advice
When selecting the Bently Nevada 9200-09-01-02-00, verify that the mounting base option (circular stud) matches your equipment's mounting hole pattern. For submerged or high-moisture areas, order the integral cable version. All units supplied by PLC Source PRO are new and original in factory packing with full 12-month warranty. For bulk pricing or custom configurations, contact ubest101 directly. This transducer is a drop-in replacement for legacy two-wire velocity probes in Bently Nevada systems.