Product Overview
The Flexem FC5-40MP-DC is a robust logic controller designed for demanding industrial automation environments. As part of the FC5 series, this Industrial Automation Module integrates 24 discrete inputs and 16 PNP transistor outputs in a compact unit, delivering precise control for machinery and process systems. With a rated supply voltage of 24VDC and built-in EtherNet communication, the FC5-40MP-DC simplifies system integration while ensuring reliable performance.
Technical Specifications
Below are the key specifications for the Flexem FC5-40MP-DC, ensuring you have the exact data needed for your application.
| Parameter |
Value |
| Rated Supply Voltage |
24VDC |
| Discrete Input Number |
24 |
| Discrete Output Type |
PNP Transistor |
| Discrete Output Number |
16 |
| Discrete Output Voltage |
DC 5V~30V |
| Discrete Output Current/Point |
2A (Max 2A) |
| Discrete Output Current/Group |
4A (Max 4A) |
| Input Rated Voltage |
DC 24V |
| Input Range |
DC 0V~28.8V |
| Input Rated Current |
7mA |
| Input Peak Voltage |
30V |
| Input Peak Current |
9mA |
| State 1 Voltage |
>15V |
| State 0 Voltage |
<5V |
| State 1 Current |
>2.5mA |
| State 0 Current |
<1.0mA |
| Isolation |
Optocoupler |
| Input Impedance |
3.3kΩ |
| Filter Time |
1ms default; 16 levels selectable from unfiltered to 100ms |
| Sensor Compatibility |
2/3-wire sensors |
| Input Type |
Source/Sink |
| Cable Length (shielded) |
Max 100m |
| Cable Length (unshielded) |
Max 50m |
| Overvoltage Protection |
Max 30V, limited to 1 hour per day |
| Output Rated Voltage |
DC 24V |
| Output Voltage Range |
DC 19.2V~28.8V |
| Output Rated Current |
2A per point |
| Output Current per Group |
4A |
| Voltage Drop |
Max 1V DC |
| Leakage Current (off) |
<5μA |
| Max Incandescent Lamp Power |
2.4W |
| Derating |
None |
| Start Time |
Max 34μs |
| Turn-off Time |
Max 250μs |
| Max Output Frequency |
1kHz |
| Short Circuit Protection |
Yes |
| Peak Short-Circuit Output Current |
1.3A |
| Self-Recovery Time |
Per 10ms |
| Clamping Voltage |
Max 39V±1V DC |
| Output Isolation |
500V AC (output to internal logic) |
| Output Cable Type |
Unshielded |
| Output Cable Length |
50m |
| Wiring Terminal |
Removable terminal block |
| Operating Temperature |
-10°C to 60°C |
| Storage Temperature |
-20°C to 70°C |
| Relative Humidity |
55%~95% (without condensation) |
| Pollution Degree |
2 (IEC60664) |
| Protection Class |
IP20 |
| Coating |
Dry film thickness ≥20μm; reinforced ≥40μm |
| Operating Altitude |
0m~3,000m |
| Transport Altitude |
≤6,000m |
| Seismic Performance |
5~13.2Hz amplitude 7mm; 13Hz~100Hz acceleration 2G; 20 times each axis |
| Impact Performance |
Semi-positive sine wave, 15G, 11ms, 6 times each axis |
Industry Applications
The FC5-40MP-DC excels in applications requiring high-speed discrete control. In packaging lines, its 16 PNP outputs can drive actuators and indicators directly, while the 24 inputs monitor sensor arrays. In material handling systems, the logic controller's fast output response (start time 34μs) ensures precise timing for sorting and diverting operations. For machine tool control, the robust environmental ratings (-10°C to 60°C) allow installation in non-climate-controlled areas.
Installation & Setup
Mount the FC5-40MP-DC on a standard DIN rail. Ensure adequate clearance for airflow and wiring access. Use the removable terminal blocks for input and output connections. For inputs, select shielded cable up to 100m or unshielded up to 50m to minimize noise. For outputs, use unshielded cable up to 50m. Set the input filter time via software, choosing from 1ms default or other levels up to 100ms to match your sensor response. Verify supply voltage is 24VDC within the specified range.
Maintenance & Reliability
Routine maintenance is minimal. Periodically check terminal connections for tightness. Keep the unit free of dust and moisture; the IP20 rating requires installation in a clean, dry enclosure. The coated PCB (dry film ≥20μm) provides added protection against harsh environments. The self-recovery short circuit protection enhances reliability, reducing downtime. Regular inspection of input/output wiring is recommended to prevent accidental shorts.
Compatibility & Integration
The Flexem FC5-40MP-DC supports EtherNet communication, enabling seamless integration with modern PLCs and SCADA systems. It is compatible with 2/3-wire sensors, offering flexibility in field device selection. The PNP transistor outputs interface directly with most industrial loads, including relays, contactors, and LED indicators.
Selection Guide
Before purchasing, confirm your system's I/O requirements match the FC5-40MP-DC's 24 inputs and 16 outputs. Check that the supply voltage is 24VDC and that your sensors are compatible with source/sink wiring. For EtherNet connectivity, ensure your network infrastructure supports the device. PLC Source PRO offers the FC5-40MP-DC as a genuine Flexem product, backed by our commitment to quality and availability.