Product Overview
When production lines demand precise control and rapid response, the Flexem FC5M-30MP-DC delivers. This logic controller from the FC5 series combines high-speed counting, pulse train output, and flexible I/O in a compact form. Rated for 24VDC supply, it handles demanding discrete control tasks with ease.
The Flexem FC5M-30MP-DC provides 18 discrete inputs (7 fast) and 12 PNP transistor outputs (6 fast), making it suitable for applications requiring both standard and high-speed actuation. Built with optocoupler isolation and robust environmental ratings, it ensures reliable operation in industrial settings.
Technical Specifications
Below are the key parameters for the Flexem FC5M-30MP-DC, ensuring you have the exact data for system design and integration.
| Parameter |
Value |
| Rated Supply Voltage |
24 VDC |
| Discrete Input Number |
18 (7 fast) |
| Discrete Output Type |
PNP Transistor |
| Discrete Output Number |
12 (6 fast) |
| Discrete Output Voltage |
DC 5V~30V |
| Discrete Output Current/Point |
2A, Max 2A |
| Discrete Output Current/Group |
4A, Max 4A |
| Input Range |
DC 0V~28.8V |
| Rated Current |
7mA |
| Isolation |
Optocoupler |
| Input Impedance |
3.3kΩ |
| Filter Time |
Default 1ms, 16 equally divided levels selectable from unfiltered to 100ms |
| Compatibility |
2/3 wire sensors |
| Input Type |
Source/Sink |
| Cable Length (Input) |
Max 100m shielded, 50m unshielded |
| Protection (overvoltage) |
Maximum 30V, limited to 1 hour per day |
| Output Type |
NPN |
| Output Voltage Range |
DC 19.2V~28.8V |
| Output Rated Current |
2A per point |
| Output Current/Group |
4A |
| Voltage Drop |
Maximum 1V DC |
| Leakage Current (off) |
<5μA |
| Max Incandescent Lamp Power |
2.4W |
| Start Time |
Maximum 34μs |
| Turn-off Time |
Maximum 250μs |
| Max Output Frequency |
1kHz |
| Short Circuit Protection |
Yes |
| Peak Short-circuit Output Current |
1.3A |
| Self-recovery after overload |
Per 10ms |
| Clamping Voltage |
DC 39V±1V |
| Isolation (Output) |
500V AC between output and internal logic |
| Output Cable Length |
Unshielded 50m |
| Fast Transistor Output Rated Voltage |
24 V DC |
| PTO Power Input Range |
19.2V~28.8V DC |
| PTO Power Reverse Protection |
Available |
| Output Type (Fast) |
NPN or PNP (based on controller model) |
| PTO/PWM Output Current |
0.5A (normal output), 0.1A (fast output) |
| Insulation Resistance |
>10 MΩ |
| Leakage Voltage |
<1.5V (at 0.1A) |
| Minimum Load Impedance |
80Ω |
| Max PTO Output Frequency (NPN) |
200kHz |
| Max PTO Output Frequency (PNP) |
100kHz |
| Max PWM Output Frequency |
50kHz |
| Duty Cycle Resolution |
Not greater than 0.5% |
| Duty Cycle Range |
0%~100% |
| Operating Mode |
Pulse/direction output |
| Fast Output Cable Length |
Maximum 5m |
| Fast Output Cable Type |
Shielded, including 24V DC power supply |
| Operating Ambient Temperature |
-10°C~60°C |
| Storage Temperature |
-20°C~70°C |
| Relative Humidity |
55%~95%, without condensation |
| Class of Pollution |
2 (IEC60664) |
| Class of Protection |
IP20 |
| Coating |
Dry film thickness ≥20μm; reinforced ≥40μm |
| Altitude (Operation) |
0m~3,000m |
| Altitude (Transportation) |
≤6,000m |
| Seismic Performance |
5~13.2Hz amplitude 7mm; 13Hz~100Hz acceleration 2G; 20 times each axis |
| Impact Performance |
15G, 11ms, 6 times each direction |
Industry Applications
The Flexem FC5M-30MP-DC excels in packaging machinery, material handling, and assembly lines where high-speed counting and precise positioning are critical. Its fast inputs (7) capture encoder signals or proximity sensor pulses without missing a beat. The 6 fast outputs generate PTO/PWM signals for stepper or servo drives, enabling accurate motion control.
For example, in a bottle filling line, the FC5M-30MP-DC counts bottles using a fast input, then triggers a PNP output to activate a filling valve. With a maximum output frequency of 1kHz for standard outputs and 200kHz for fast NPN outputs, it handles rapid cycling with ease.
Moreover, the module's wide operating temperature range (-10°C to 60°C) and robust coating make it suitable for harsh factory floors. Its IP20 protection and pollution class 2 rating ensure reliable performance in typical industrial environments.
Installation & Setup Guidance
Mount the Flexem FC5M-30MP-DC on a standard DIN rail inside an IP20 enclosure. Use removable terminal blocks for wiring. For inputs, connect 2/3-wire sensors respecting source/sink configuration. Use shielded cable up to 100m for inputs to minimize noise; for outputs, unshielded cable up to 50m is acceptable. For fast outputs, always use shielded cable with a maximum length of 5m, and include the 24V DC power supply in the same cable to ensure signal integrity.
Ensure the supply voltage is within 19.2V~28.8V DC to avoid overvoltage stress. The overvoltage protection handles up to 30V but only for 1 hour per day; prolonged exposure may damage the module. Verify wiring polarity to prevent reverse voltage issues.
Maintenance & Reliability
Regularly inspect terminal connections for tightness and signs of corrosion. Keep the enclosure clean to maintain IP20 protection. The module's coated PCB (≥20μm dry film) resists moisture and dust, extending service life. With no derating required, the FC5M-30MP-DC operates at full capacity across its temperature range. Self-recovery from short circuits occurs within 10ms, minimizing downtime. For maximum reliability, avoid exceeding the 30V overvoltage limit and ensure adequate ventilation to stay within the -10°C to 60°C operating range.
Compatibility & Integration
The Flexem FC5M-30MP-DC is part of the FC5 series, designed for standalone or networked control. It supports source/sink input types and PNP transistor outputs, making it compatible with a wide range of industrial sensors and actuators. For communication, the module includes an EtherNet port for integration into plant networks, enabling remote monitoring and data exchange. While specific protocols are not listed, the Ethernet interface allows connection to standard industrial networks, facilitating centralized control.
Selection Guide & Purchasing Advice
Before purchasing the Flexem FC5M-30MP-DC, verify your I/O count and speed requirements. The module offers 18 inputs and 12 outputs, with fast channels for high-speed tasks. Confirm your output type—PNP transistor outputs require a common positive supply. If you need NPN outputs, check the controller model variant. For motion control, ensure your drive accepts PTO/PWM signals at the required frequency. Always source from a trusted supplier to guarantee genuine parts and reliable support. PLC Source PRO provides authentic automation spares with fast delivery, ensuring your operations stay on schedule.