{"product_id":"schneider-tsxaey414-analog-input-module-for-tsx-micro-plc","title":"Schneider TSXAEY414 Analog Input Module for TSX Micro PLC","description":"\u003ch2\u003eProduct Introduction\u003c\/h2\u003e\u003cp\u003eWhen precise analog measurements are critical in industrial automation, the \u003cstrong\u003eSchneider TSXAEY414\u003c\/strong\u003e provides a reliable 4-channel analog input solution for TSX Micro PLCs. The \u003cstrong\u003eSchneider TSXAEY414\u003c\/strong\u003e supports a wide variety of input types including current (4–20 mA), voltage (±10 V, 0–10 V, 0–5 V, 1–5 V), thermocouples (B, E, J, K, L, N, R, S, T, U), resistors (0–400 Ω, 0–3850 Ω), and temperature probes (Pt100, Pt1000, Ni1000). Its comprehensive voltage isolation (2830 Vrms between channels and bus, 1780 Vrms to ground) ensures operational integrity in noisy environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications Breakdown\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eSchneider TSXAEY414\u003c\/strong\u003e delivers a nominal read cycle time of 550 ms and uses 16-bit analog-to-digital conversion for accurate measurements. Key specifications from the manufacturer include:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTSXAEY414\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003ctd\u003e4 high-level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\/Digital Conversion\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Read Cycle Time\u003c\/td\u003e\n\u003ctd\u003e550 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Voltage (between channels)\u003c\/td\u003e\n\u003ctd\u003e415 V AC or 200 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (channels to bus)\u003c\/td\u003e\n\u003ctd\u003e2830 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (channels to ground)\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e660 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (operation)\u003c\/td\u003e\n\u003ctd\u003e10 to 95% without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003e-30 to 30 V (state 1), -15 to 15 V (state 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eSchneider TSXAEY414\u003c\/strong\u003e excels in process control environments requiring accurate temperature, pressure, and flow measurements. For example, in a chemical plant, the module can read multiple thermocouple types (e.g., Type K or J) to monitor reactor temperatures, while its 550 ms cycle time provides timely data for control loops. In HVAC systems, the module handles 4–20 mA transmitters for pressure and humidity sensing, and its built-in overvoltage protection safeguards against spikes.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eInstall the \u003cstrong\u003eSchneider TSXAEY414\u003c\/strong\u003e in a standard slot of a TSX Micro PLC rack. Connect field wiring using the screw terminal block, ensuring proper polarity for current and voltage inputs. For thermocouple connections, use appropriate extension wire and maintain cold-junction compensation if required. The module draws 660 mA from the 5 V DC bus, so verify the power supply capacity. No special software configuration is needed beyond standard PLC programming tools.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore purchasing the \u003cstrong\u003eSchneider TSXAEY414\u003c\/strong\u003e, verify that your TSX Micro PLC backplane has an available slot and can supply sufficient 5 V current. This module is ideal for upgrading older analog input modules with limited input type support. UBEST Automation, your trusted industrial automation parts supplier, offers this module with fast shipping and genuine Schneider quality. Contact us to confirm compatibility with your specific system.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default","offer_id":44404083032163,"sku":"TSXAEY414","price":266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/TSXAEY414-1.jpg?v=1785026992","url":"https:\/\/www.plcsourcepro.com\/products\/schneider-tsxaey414-analog-input-module-for-tsx-micro-plc","provider":"PLC Source PRO","version":"1.0","type":"link"}