{"product_id":"schneider-atv71hd22n4-industrial-automation-module-stable","title":"Schneider ATV71HD22N4 Industrial Automation Module - Stable","description":"\u003ch2\u003eProduct Introduction\u003c\/h2\u003e\u003cp\u003eThe Schneider ATV71HD22N4 variable speed drive delivers robust motor control for complex, high-power machines. With a power rating of 22 kW (30 hp) and 480 V AC three-phase input, this drive handles demanding industrial applications. Part of the Altivar 71 product line, the ATV71HD22N4 integrates advanced protection features to prevent common failure modes, ensuring reliable operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications Breakdown\u003c\/h2\u003e\u003cp\u003eThe following key parameters define the Schneider ATV71HD22N4. All values come directly from the product specifications.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Speed Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eAltivar 71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eATV71HD22N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e3389118069503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e75.00 lbs (34.02 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power\u003c\/td\u003e\n\u003ctd\u003e22 kW \/ 30 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Status\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe Schneider ATV71HD22N4 excels in environments where protection against electrical faults is critical. Its integrated protections—such as overcurrent, overvoltage, and phase loss detection—prevent motor and drive damage in pumping, conveyor, and HVAC systems. For example, in a wastewater treatment plant, the drive’s ability to withstand line supply overvoltage and input phase breaks ensures continuous operation, reducing costly downtime.\u003c\/p\u003e\u003ch2\u003eCompatibility \u0026amp; Integration\u003c\/h2\u003e\u003cp\u003eThis Schneider ATV71HD22N4 drive supports Modbus and CANopen communication protocols via RJ45 and SUB-D connectors. It integrates seamlessly with PLCs and SCADA systems, enabling remote monitoring and control. The drive also accepts optional communication cards for DeviceNet, EtherNet\/IP, and Profibus DP, offering flexibility for various network architectures.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eMount the Schneider ATV71HD22N4 vertically within ±10 degrees. Use the provided terminals: 2.5 mm² for control signals (AI1-\/AI1+, AI2, AO1, relay outputs) and 50 mm² for power connections (L1\/R, L2\/S, L3\/T, U\/T1, V\/T2, W\/T3). Apply tightening torque of 5.3 lbf.in for control terminals and 106.2 lbf.in for power terminals. For shielded motor cables, keep lengths under 100 m to maintain EMC performance.\u003c\/p\u003e\u003ch2\u003eTroubleshooting \u0026amp; Common Issues\u003c\/h2\u003e\u003cp\u003eThe Schneider ATV71HD22N4 includes diagnostic LEDs and numerous protection functions to simplify troubleshooting. If the drive trips on overvoltage, check the DC bus voltage and braking resistor circuit. For input phase loss errors, verify incoming power quality and connections. The drive’s thermal protection prevents overheating; ensure ambient temperature stays within 0–50°C. For reliable sourcing of replacement drives, visit PLC Source PRO at ubest101.myshopify.com – a trusted partner for industrial automation spares.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default","offer_id":44417223721059,"sku":"ATV71HD22N4","price":272.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/ATV71HD22N4_067ac8e7-eb91-4f70-a756-ed63d313958a.jpg?v=1785269945","url":"https:\/\/www.plcsourcepro.com\/products\/schneider-atv71hd22n4-industrial-automation-module-stable","provider":"PLC Source PRO","version":"1.0","type":"link"}