{"product_id":"ge-ic200mdl650-discrete-input-module-32-point-versamax","title":"GE IC200MDL650 Discrete Input Module 32-Point VersaMax","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe GE IC200MDL650 Discrete Input Module is a 32-point input module from the VersaMax I\/O series. Designed to interface with DC input devices such as limit switches, pushbuttons, and proximity sensors, this module supports both positive and negative logic wiring configurations. Its configurable input filter times (0 ms, 1.0 ms, 7.0 ms) help eliminate false signals caused by switch bounce and electrical noise, making it a reliable choice for demanding industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications Breakdown\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage, Nominal\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage, Range\u003c\/td\u003e\n\u003ctd\u003e0–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e15–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e2.0–5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e0–0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e0.5 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Times (configurable)\u003c\/td\u003e\n\u003ctd\u003e0 ms, 1.0 ms, 7.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup-to-Group Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e50 mA max at 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Groups\u003c\/td\u003e\n\u003ctd\u003e4 groups of 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eOne per point + OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eHow the IC200MDL650 Prevents Common Input Failures\u003c\/h2\u003e\u003cp\u003eIn industrial settings, switch bounce and electrical noise can cause false triggering of input modules. The GE IC200MDL650 addresses this with three selectable filter times: 0 ms (no filter), 1.0 ms (default), and 7.0 ms (heavy filtering). By choosing the appropriate filter, operators can eliminate unintentional signals from contact bounce or transient noise. Additionally, group-to-group isolation of 250 VAC continuous prevents cross-channel interference, ensuring reliable operation even in electrically noisy environments. The individual LED indicators per point allow quick visual identification of module and channel status, reducing troubleshooting time.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidelines\u003c\/h2\u003e\u003cp\u003eInstall the GE IC200MDL650 module onto a standard DIN rail. It supports both horizontal and vertical mounting orientations. The module draws power from the PLC backplane (5 V, 50 mA max) and does not require an external power supply. Field wiring connects to the input channels via compatible I\/O carriers. Each group of eight channels can be wired for positive or negative logic. Ensure the input voltage stays within the 0–30 VDC range; nominal is 24 VDC. The module has no derating at 24 VDC, but ambient temperature and orientation may affect performance. Verify proper grounding and isolation per system requirements.\u003c\/p\u003e\u003ch2\u003eReal-World Applications\u003c\/h2\u003e\u003cp\u003eThe GE IC200MDL650 is ideal for applications where reliable input detection is critical. Examples include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor Systems:\u003c\/strong\u003e Monitor limit switches and photo-eyes in material handling. Use 7.0 ms filter to ignore vibration-induced spurious signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Detect presence or position of products with proximity sensors. The 1.0 ms default filter balances speed and noise rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated Assembly:\u003c\/strong\u003e Interface with pushbuttons and two-hand controls. Positive\/negative logic flexibility simplifies integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eWhen selecting the GE IC200MDL650, confirm that your PLC backplane supports VersaMax I\/O modules. Verify the required input voltage and filter settings for your application. The module ships as a single unit; I\/O carriers and cables are sold separately. For genuine, new or refurbished modules with assured quality, purchase from UBEST Automation (ubest101.myshopify.com). UBEST Automation provides industrial automation spares with fast shipping and expert support.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default","offer_id":44403986628707,"sku":"IC200MDL650","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/IC200MDL650_1.jpg?v=1785018350","url":"https:\/\/www.plcsourcepro.com\/products\/ge-ic200mdl650-discrete-input-module-32-point-versamax","provider":"PLC Source PRO","version":"1.0","type":"link"}