{"product_id":"ge-ic200alg630-versamax-7-channel-thermocouple-millivolt-input-module","title":"GE IC200ALG630 VersaMax 7-Channel Thermocouple \/ Millivolt Input Module","description":"\u003ch2\u003eProduct Introduction\u003c\/h2\u003e\u003cp\u003eWhen thermocouple wiring degrades or cold junction errors threaten measurement accuracy, the \u003cstrong\u003eGE IC200ALG630\u003c\/strong\u003e delivers robust diagnostics and high-resolution signal conversion to maintain process reliability. This 7-channel analog input module from the VersaMax I\/O series handles thermocouple types J, K, T, S, and R, as well as millivolt signals from ±19.5 mV to ±625 mV. With 16-bit resolution and per-channel diagnostics, the \u003cstrong\u003eIC200ALG630\u003c\/strong\u003e prevents costly downtime by detecting open thermocouples, over\/under range conditions, and thermistor faults.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (GE Intelligent Platforms \/ Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIC200ALG630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e7 (thermocouple or millivolt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple J, K, T, S, R; Millivolt ±19.5 mV, ±39 mV, ±78.125 mV, ±156.25 mV, ±312.5 mV, ±625 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits (15 bits plus sign)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 25°C\u003c\/td\u003e\n\u003ctd\u003e±0.2% voltage measurement; ±0.15% temperature measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e60 ms per channel @ 60 Hz; 70 ms per channel @ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e125 mA from 5 VDC and 3.3 VDC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute (optical and frame-to-ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOpen Thermocouple, over\/under range, high\/low alarm, thermistor error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eOK LED (green when active, amber on fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eGE IC200ALG630\u003c\/strong\u003e excels in temperature monitoring and low-level millivolt signal acquisition. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Furnace Control\u003c\/strong\u003e – Type K and R thermocouples provide reliable temperature feedback; open thermocouple detection alerts operators to sensor failures before product quality suffers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Reactor Monitoring\u003c\/strong\u003e – High-accuracy (±0.15%) temperature measurement ensures precise process control, while over\/under range alarms prevent unsafe excursions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Signal Integration\u003c\/strong\u003e – Capture millivolt outputs from pressure or flow transducers with 16-bit resolution and per-channel diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eIC200ALG630\u003c\/strong\u003e mounts directly onto the VersaMax backplane, drawing power from the 5 VDC and 3.3 VDC supplies. For thermocouple connections, use shielded twisted-pair cables to minimize noise. The module offers four cold junction compensation options: no compensation, remote, fixed, or local (internal). Select the appropriate mode via software configuration. Ensure the module’s operating environment stays within 0–60 °C for reliable performance.\u003c\/p\u003e\n\n\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eRoutine checks should include verifying the OK LED status – green indicates normal operation, amber signals a fault. The built-in diagnostics automatically detect open thermocouples, over\/under range conditions, and thermistor errors, reducing manual inspection frequency. Because the \u003cstrong\u003eGE IC200ALG630\u003c\/strong\u003e does not experience thermal derating, it maintains accuracy even near its 60 °C upper limit. Periodic cleaning of the module’s front panel and connectors helps sustain isolation integrity.\u003c\/p\u003e\n\n\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore ordering, confirm that your system uses a VersaMax I\/O backplane and that the required thermocouple types (J, K, T, S, R) or millivolt ranges match your sensors. The \u003cstrong\u003eIC200ALG630\u003c\/strong\u003e is a replacement for legacy GE Fanuc modules and is now supported by Emerson Automation. For genuine spares and fast shipping, source from \u003cstrong\u003eUBEST Automation\u003c\/strong\u003e – your trusted partner for industrial automation parts. Visit ubest101.myshopify.com to check stock and request a quote.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat thermocouple types does the IC200ALG630 support?\u003c\/h3\u003e\u003cp\u003eThe module supports Types J, K, T, S, and R thermocouples, as well as millivolt signals from ±19.5 mV to ±625 mV.\u003c\/p\u003e\u003ch3\u003eHow many channels does the IC200ALG630 have?\u003c\/h3\u003e\u003cp\u003eIt has 7 input channels, each configurable for thermocouple or millivolt inputs.\u003c\/p\u003e\u003ch3\u003eWhat diagnostic features are available?\u003c\/h3\u003e\u003cp\u003eDiagnostics include open thermocouple detection, over\/under range alarms, high\/low alarms, and thermistor error detection.\u003c\/p\u003e\u003ch3\u003eWhat is the accuracy of the IC200ALG630?\u003c\/h3\u003e\u003cp\u003eAccuracy is ±0.2% on voltage measurement and ±0.15% on temperature measurement at 25°C.\u003c\/p\u003e\u003ch3\u003eIs the IC200ALG630 compatible with Emerson automation systems?\u003c\/h3\u003e\u003cp\u003eYes, the module was originally by GE Intelligent Platforms and is now under Emerson Automation, remaining compatible with the VersaMax I\/O platform.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default","offer_id":44403976700003,"sku":"IC200ALG630","price":288.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/IC200ALG630_1.jpg?v=1785017483","url":"https:\/\/www.plcsourcepro.com\/products\/ge-ic200alg630-versamax-7-channel-thermocouple-millivolt-input-module","provider":"PLC Source PRO","version":"1.0","type":"link"}