{"product_id":"bently-nevada-330905-00-08-10-02-05-industrial-automation-module","title":"Bently Nevada 330905-00-08-10-02-05 Industrial Automation Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eWhen process compressor applications demand reliable vibration monitoring, the \u003cstrong\u003eBently Nevada 330905-00-08-10-02-05\u003c\/strong\u003e 3300 NSv Proximity Probe delivers precise, repeatable measurements. This industrial automation module is a direct replacement for the previous 3300 RAM probe, offering enhanced chemical resistance and superior side-view characteristics. With a 1.0-meter (39-inch) total length and M10x1 thread without armor, this probe is engineered for demanding environments.\u003c\/p\u003e\u003cp\u003eThe 330905-00-08-10-02-05 features a miniature coaxial ClickLoc connector and standard cable, ensuring secure and quick installation. Its increased chemical resistance compared to the 3300 RAM probe makes it ideal for process compressor applications where exposure to aggressive media is common.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMechanically and electrically interchangeable with Bently Nevada's previous 3300 RAM probe and extension cable.\u003c\/li\u003e\n\u003cli\u003eSuperior side-view characteristics compared to the 3000-series 190 probe.\u003c\/li\u003e\n\u003cli\u003eEnhanced chemical resistance for process compressor use.\u003c\/li\u003e\n\u003cli\u003eProbe tip material: Polyphenylene sulfide (PPS).\u003c\/li\u003e\n\u003cli\u003eProbe case material: AISI 304 stainless steel (SST).\u003c\/li\u003e\n\u003cli\u003eOperating and storage temperature range: -52°C to +177°C (-62°F to +351°F).\u003c\/li\u003e\n\u003cli\u003eProbe pressure seal with Viton O-ring (not pressure tested prior to shipment).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cp\u003eThe following specifications are directly from the manufacturer for the \u003cstrong\u003eBently Nevada 330905-00-08-10-02-05\u003c\/strong\u003e 3300 NSv Proximity Probe:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), starting at approximately 0.25 mm (10 mils) from target (0.25 to 1.75 mm \/ 10 to 70 mils, approx. -1 to -13 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5%\/-20% including interchangeability error (measured in 0.25 mm increments over linear range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.06 mm (±2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305 meters \/ 1000 feet of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe DC Resistance (1.0 m length)\u003c\/td\u003e\n\u003ctd\u003e4.2 ± 0.5 ohms (center conductor to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable DC Resistance\u003c\/td\u003e\n\u003ctd\u003eCenter conductor: 0.220 Ω\/m (0.067 Ω\/ft); Shield: 0.066 Ω\/m (0.020 Ω\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm² (16 to 24 AWG) [0.25 to 0.75 mm² (18 to 23 AWG) with ferrules]; recommended three-conductor shielded triad cable; maximum length 305 m (1000 ft) between sensor and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Size (flat target)\u003c\/td\u003e\n\u003ctd\u003eMinimum: 8.9 mm (0.35 in) diameter; Recommended minimum: 13 mm (0.5 in) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable Specification\u003c\/td\u003e\n\u003ctd\u003e75 Ω coaxial, fluoroethylene propylene (FEP) insulated; available total probe lengths: 0.5, 1, 5, or 7 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Torque\u003c\/td\u003e\n\u003ctd\u003eFinger tight; Maximum torque: 0.56 N•m (5 in•lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius (with or without SST armor)\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Torque (M10x1, first three threads)\u003c\/td\u003e\n\u003ctd\u003eMaximum rated: 22.6 N•m (200 in•lb); Recommended: 7.5 N•m (66 in•lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Thread Engagement\u003c\/td\u003e\n\u003ctd\u003eM10x1, maximum length: 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330905-00-08-10-02-05\u003c\/strong\u003e is designed for critical rotating machinery monitoring. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Compressors:\u003c\/strong\u003e The increased chemical resistance allows reliable operation in aggressive media environments, reducing downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbomachinery:\u003c\/strong\u003e Shaft vibration and axial position monitoring in steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps and Fans:\u003c\/strong\u003e Detecting shaft displacement and dynamic motion to prevent catastrophic failures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIn each case, the probe's linear range and high accuracy (ISF of 7.87 V\/mm) ensure precise data for condition monitoring systems.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eProper installation is critical for optimal performance of the \u003cstrong\u003e330905-00-08-10-02-05\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMount the probe using the M10x1 thread; apply the recommended torque of 7.5 N•m (66 in•lb) for the first three threads. Do not exceed 22.6 N•m (200 in•lb).\u003c\/li\u003e\n\u003cli\u003eSet the initial gap to 1.0 mm (40 mils) from the target surface. Use shims or a feeler gauge for accuracy.\u003c\/li\u003e\n\u003cli\u003eEnsure the target size meets the recommended minimum of 13 mm (0.5 in) diameter. For smaller shafts, consult the scale factor adjustment notes.\u003c\/li\u003e\n\u003cli\u003eRoute the probe cable with a minimum bend radius of 25.4 mm (1.0 in) to avoid damage.\u003c\/li\u003e\n\u003cli\u003eUse the specified ClickLoc connector; ensure it is fully seated and locked.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eRoutine inspection of the probe and cable is essential for long-term reliability. Check for signs of chemical attack, especially in process compressor environments. Inspect the cable for cuts or abrasions, and verify the connector integrity periodically. The probe's PPS tip and stainless steel case offer excellent durability, but regular visual checks can prevent unexpected failures. The wide operating temperature range (-52°C to +177°C) ensures stable performance in extreme conditions, reducing lifecycle costs.\u003c\/p\u003e\u003ch2\u003eCompatibility \u0026amp; Integration\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330905-00-08-10-02-05\u003c\/strong\u003e is fully compatible with Bently Nevada's 3300 XL NSv Proximitor Sensor and existing 3300 series monitoring systems. It is mechanically and electrically interchangeable with the previous 3300 RAM probe and extension cable, allowing seamless upgrades. The probe's output can be integrated into most vibration monitoring systems that accept eddy-current probe signals. For field wiring, use a three-conductor shielded triad cable up to 305 meters (1000 feet) between the sensor and monitor.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore purchasing, verify your system's requirements: thread size (M10x1), total length (1.0 meter), connector type (ClickLoc), and agency approval (Multiple Approvals). Confirm that the probe's linear range and gap setting match your application's needs. PLC Source PRO ensures you receive a new, original product in factory packing with a 12-month warranty. For bulk orders or custom pressure testing, contact our sales team for assistance.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default","offer_id":44482512420963,"sku":"330905-00-08-10-02-05","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/330905-00-16-10-02-05_41175208-838f-4468-ae91-c6fcb327a915.jpg?v=1786811977","url":"https:\/\/www.plcsourcepro.com\/products\/bently-nevada-330905-00-08-10-02-05-industrial-automation-module","provider":"PLC Source PRO","version":"1.0","type":"link"}