{"product_id":"bently-nevada-330173-00-18-10-02-05-industrial-automation-module","title":"Bently Nevada 330173-00-18-10-02-05 Guide: Key Specs \u0026 Features","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eWhen a legacy 3300-series proximity probe starts delivering erratic displacement readings, upgrading to the Bently Nevada 330173-00-18-10-02-05 restores accurate vibration monitoring. This 3300 5mm Probe uses an M8 x 1 thread and arrives without armor, making it suitable for internal machine train measurements. The miniature coaxial ClickLoc connector with standard cable simplifies the replacement process, so you can swap out older transducers without redesigning your monitoring loop.\u003c\/p\u003e\u003cp\u003eThis probe features a polyphenylene sulfide (PPS) tip and a case machined from AISI 303 or 304 stainless steel. The 1.0 metre (3.3 feet) total length, 180 mm overall case length, and 00 mm unthreaded length match common 3300 system layouts. Because the Bently Nevada 330173-00-18-10-02-05 is made in the U.S.A., you get consistent manufacturing quality for critical machinery protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 5mm Probe, M8 x 1 thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e00 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.323 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe DC Resistance (1.0 m)\u003c\/td\u003e\n\u003ctd\u003e7.59 ± 0.50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable\u003c\/td\u003e\n\u003ctd\u003e75 Ω triaxial, FEP insulated, available in 0.5, 1, 2, 5, or 9 m lengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Torque\u003c\/td\u003e\n\u003ctd\u003e5.1 N·m recommended; 7.3 N·m maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector-to-Connector Torque\u003c\/td\u003e\n\u003ctd\u003e0.565 N·m maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-35°C to +177°C (-31°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Engagement\u003c\/td\u003e\n\u003ctd\u003eM8x1, maximum 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eInstallation Guidance\u003c\/h2\u003e\u003cp\u003eInstall the Bently Nevada 330173-00-18-10-02-05 with care to avoid thread damage. Engage the M8 x 1 thread to a maximum of 12 mm. Apply a probe case torque of 5.1 N·m (45 in·lb) recommended, and never exceed 7.3 N·m (65 in·lb). For connector-to-connector joints, use a maximum torque of 0.565 N·m (0.42 ft·lbf). Keep the cable bend radius above 25.4 mm (1.0 in) to prevent internal wire fatigue. These torque limits protect both the probe and the surrounding equipment.\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eMaintaining the 330173-00-18-10-02-05 is straightforward when you monitor its operating environment. Do not expose the probe to temperatures below -34°C (-30°F); the pressure seal may fail prematurely. The upper limit is +177°C (+351°F), so verify the bearing housing or casing temperature stays within this range. Periodically inspect the gold-plated connectors, which are made from gold-plated brass or gold-plated beryllium copper, for corrosion or looseness. Replacing worn probes before failure reduces unplanned downtime and protects downstream machinery.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore purchasing, confirm that the Bently Nevada 330173-00-18-10-02-05 matches your system requirements. Verify the unthreaded length (00 mm), overall case length (180 mm), and total length (1.0 m). Make sure your extension cable uses the miniature coaxial ClickLoc connector. The agency approval option 05 indicates multiple approvals, so check that these align with your site certification needs. For current stock and availability, contact PLC Source PRO.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default","offer_id":44427424432227,"sku":"330173-00-18-10-02-05","price":221.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/330173_9d48411b-183c-4b3c-9bf5-6aeec27caf9a.jpg?v=1785474653","url":"https:\/\/www.plcsourcepro.com\/products\/bently-nevada-330173-00-18-10-02-05-industrial-automation-module","provider":"PLC Source PRO","version":"1.0","type":"link"}