{"product_id":"abb-v18345-1027420001-industrial-automation-module-reliable","title":"ABB V18345-1027420001 Industrial Automation Module - Reliable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe ABB V18345-1027420001 is a precision electro-pneumatic positioner engineered for demanding industrial automation environments. This model combines robust aluminum construction with IP 65 (NEMA 4X) protection, making it suitable for linear actuators per DIN\/IEC 534\/NAMUR and rotary actuators per VDI\/VDE 3845. With a 4...20 mA two-wire input and GOST Russia Ex II 2 G EEx ib II C T6 explosion protection, the V18345-1027420001 delivers reliable, fail-safe positioning even in hazardous areas.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElectro-Pneumatic Positioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase \/ Mounting\u003c\/td\u003e\n\u003ctd\u003eAluminium, varnished, IP 65 (NEMA 4X); for linear actuators acc. to DIN\/IEC 534\/NAMUR or rotary actuators acc. to VDI\/VDE 3845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput \/ Communication\u003c\/td\u003e\n\u003ctd\u003e4...20 mA, two-wire with connector plug for LKS adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eGOST Russia Ex II 2 G EEx ib II C T6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput \/ Safe Position\u003c\/td\u003e\n\u003ctd\u003eDouble acting, fail-safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eCable: Thread 1\/2-14 NPT; Air pipe: Thread 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (D x W x H)\u003c\/td\u003e\n\u003ctd\u003e16.85 cm x 9.29 cm x 8.95 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003eNominal 4...20 mA; split range 20%–100%; max 25 mA \/ 30 V; min 3.4 mA (without analog pos. feedback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage at 20 mA\u003c\/td\u003e\n\u003ctd\u003e8.7 V DC (without explosion protection); 9.7 V DC (intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance at 20 mA\u003c\/td\u003e\n\u003ctd\u003e435 ohms (without explosion protection); 485 ohms (intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003ctd\u003eControl voltage 24 V DC (12...30 V DC); logical '0' 0...10 V DC; logical '1' 12...30 V DC; max current 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output (NAMUR)\u003c\/td\u003e\n\u003ctd\u003eSupply 5...11 V DC; logical '0' \u0026lt; 1.0 mA; logical '1' \u0026gt; 2.0 mA; configurable direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0...6 bar (0...90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Capacity\u003c\/td\u003e\n\u003ctd\u003eAt 1.4 bar: 5.0 kg\/h (3.9 Nm3\/h, 2.3 scfm); at 6 bar: 13 kg\/h (10 Nm3\/h, 6.0 scfm) with booster on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAngle of Rotation\u003c\/td\u003e\n\u003ctd\u003e25...120° (rotary, optionally 270°); 25...60° (linear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTravel Time Prolongation\u003c\/td\u003e\n\u003ctd\u003e0...200 s, separately per direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable fail-safe operation:\u003c\/strong\u003e In case of electrical power failure, the actuator is vented or blocked, ensuring a safe plant state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible mounting:\u003c\/strong\u003e Compatible with linear and rotary actuators, with integral mounting options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion protection:\u003c\/strong\u003e GOST Ex approval (EEx ib IIC T6) allows installation in hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise control:\u003c\/strong\u003e Configurable travel limits and positioning time limits provide accurate valve positioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit range capability:\u003c\/strong\u003e Supports split range configuration between 20% and 100% of nominal range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe ABB V18345-1027420001 is ideal for process industries where precise valve control and safety are critical. Common applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil \u0026amp; Gas:\u003c\/strong\u003e Regulating flow in pipelines and separators, especially in explosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Processing:\u003c\/strong\u003e Controlling corrosive media with fail-safe actuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Managing steam and cooling water valves with high reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eWhen installing the V18345-1027420001, ensure the mounting bracket matches the actuator standard (NAMUR or VDI\/VDE 3845). Connect the air supply via the 1\/4-18 NPT port and electrical wiring through the 1\/2-14 NPT cable entry. Configure the input signal range (4...20 mA) and split range settings according to your control system. For double-acting actuators, verify that the air venting\/blocking behavior aligns with your fail-safe requirements.\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eThe aluminum case and IP 65 rating protect the positioner from dust and water ingress, reducing maintenance frequency. Periodically inspect the air connections for leaks and verify the electrical connections remain secure. Calibration checks every 6-12 months help maintain accuracy, especially in high-vibration environments. The robust design minimizes downtime, ensuring long-term operational efficiency.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore purchasing the ABB V18345-1027420001, verify your actuator's mounting interface and air supply pressure. Confirm whether you need the optional analog or digital position feedback modules (this unit comes without them). For hazardous area installations, check that the GOST Ex rating matches your zone classification. PLC Source PRO offers this genuine ABB V18345-1027420001 positioner with fast shipping and quality assurance.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default","offer_id":44447409963107,"sku":"V18345-1027420001","price":286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/V18345-1010121001_0b78c6cd-def7-4f1c-b570-e1184dd50b1a.jpg?v=1785966751","url":"https:\/\/www.plcsourcepro.com\/products\/abb-v18345-1027420001-industrial-automation-module-reliable","provider":"PLC Source PRO","version":"1.0","type":"link"}