{"product_id":"150-f60nbdb-industrial-automation-module-by-allen-bradley","title":"150-F60NBDB Industrial Automation Module by Allen-Bradley","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Allen-Bradley 150-F60NBDB SMC Flex Smart Motor Controller is a versatile soft starter engineered for demanding industrial applications. With a 60 A rating and support for 10-40 Hp motors at 460V AC, this controller delivers precise, reliable motor control. It features a built-in display for real-time status indication, including stopped, starting, stopping, at speed, alarm, and fault states. The 150-F60NBDB integrates advanced protection and control options, making it an ideal choice for pump control and other critical processes.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cp\u003eThe Allen-Bley 150-F60NBDB (note: correct model is Allen-Bradley 150-F60NBDB) offers a comprehensive set of specifications that ensure robust performance in a variety of operating conditions. Key parameters include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Rating:\u003c\/strong\u003e 60 A, 10-40 Hp @ 460V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100...240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e 200...480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Classes:\u003c\/strong\u003e 10, 15, 20, and 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Current Rating:\u003c\/strong\u003e 117% of motor FLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDV\/DT Protection:\u003c\/strong\u003e RC snubber network for power circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Metal oxide varistors: 220 J (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection Device Performance (SCPD) Type:\u003c\/strong\u003e Type 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Bypass:\u003c\/strong\u003e True\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Single direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open type\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe 150-F60NBDB also includes a tachometer input (0...5V DC @ 4.5V DC = 100% Speed) and supports up to 6 PTC sensors for thermal protection. Its auxiliary contacts are rated at 3A @ 120V AC and 1.5A @ 240V AC, with a conventional thermal current of 5 A.\u003c\/p\u003e\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe Allen-Bradley 150-F60NBDB excels in applications requiring soft starting and stopping to reduce mechanical stress and electrical surges. Typical use cases include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump Control:\u003c\/strong\u003e The 150-F60NBDB's dedicated pump control option minimizes water hammer and pressure spikes, extending pump life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor Systems:\u003c\/strong\u003e Smooth acceleration and deceleration protect product integrity and reduce wear on gearboxes and belts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Equipment:\u003c\/strong\u003e Fans and blowers benefit from controlled start-up, preventing belt slippage and duct overpressure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWith a maximum line-connected motor power of 50 Hp @ 575V AC and delta-connected power of 75 Hp @ 460V AC, this controller handles a wide range of motor sizes.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eProper installation ensures optimal performance of the Allen-Bradley 150-F60NBDB. Follow these guidelines:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the controller in a clean, dry, and well-ventilated enclosure. Maintain adequate clearance for airflow around the heatsink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use the specified cable sizes: lower line side and load side 0.8...2.5 mm² (18...14 AWG), upper line side 2.5...95 mm² (14...3 AWG), and upper load side 2.5...50 mm² (14...1 AWG). Tighten power terminals to 14.7 Nm (130 in-lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Wiring:\u003c\/strong\u003e For control circuits, ensure input OFF-state current is below 10 mA AC and 3 mA DC, and input ON-state current is 20 mA @ 120V AC or 40 mA @ 240V AC. Use M3 screw clamps for control terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Install appropriate short-circuit protection devices, such as standard fuses, circuit breakers, or high-capacity time-delay Class CC\/J\/L fuses. The controller supports a maximum high-capacity available fault current of 70kA @ 600V with Class J or L fuses for inside delta connected motors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eRegular maintenance keeps the Allen-Bradley 150-F60NBDB operating reliably. Consider the following:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Periodically check all power and control connections for tightness and signs of overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e The controller operates in temperatures from -5 to 50 °C (23 to 122 °F) and humidity of 5...95% (noncondensing). Ensure the enclosure maintains these conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaning:\u003c\/strong\u003e Keep the heatsink and fan free of dust and debris to prevent overheating. The heatsink fan rating is 20VA @ 110\/120V AC or 220\/240V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration and Shock:\u003c\/strong\u003e The 150-F60NBDB withstands 1.0 G peak vibration and 15 G shock, but mounting should minimize exposure to excessive mechanical stress.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWith a steady-state heat dissipation of 97 W, proper ventilation is crucial for long-term reliability.\u003c\/p\u003e\u003ch2\u003eCompatibility \u0026amp; Integration\u003c\/h2\u003e\u003cp\u003eThe Allen-Bradley 150-F60NBDB integrates seamlessly into existing motor control systems. It supports:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 100...240V AC, making it compatible with a wide range of control power supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTC Inputs:\u003c\/strong\u003e Up to 6 PTC sensors for motor thermal protection, with response time of 800 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e Four auxiliary contacts (19\/20, 29\/30, 31\/32, 33\/34) for status feedback to PLCs or DCS systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e For the control module, a minimum Allen-Bradley 1606-XLP50E power supply @ 24V DC (-15%, +10%) is recommended.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe controller's electromagnetic relay control circuit and programmable NO\/NC contacts provide flexible integration with various automation architectures.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eWhen selecting the Allen-Bradley 150-F60NBDB, verify your motor's full-load current and voltage to ensure the controller's rating matches. Consider the following:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Connection:\u003c\/strong\u003e Determine if your motor is line-connected or delta-connected. The 150-F60NBDB supports line-connected motors up to 50 Hp @ 575V AC and delta-connected motors up to 75 Hp @ 460V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Requirements:\u003c\/strong\u003e The unit includes integrated overload protection, but you must supply appropriate external short-circuit protection devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Features:\u003c\/strong\u003e The SMB smart motor braking control is available as an option, providing adjustable braking current from 0...400% of motor FLC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor a reliable supply of genuine Allen-Bradley 150-F60NBDB controllers and expert support, choose PLC Source PRO as your trusted partner.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default","offer_id":44434084429923,"sku":"150-F60NBDB","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/150-F60NBRD_8257760e-01cf-4a46-99cb-8673fc2bbd6a.jpg?v=1785737413","url":"https:\/\/www.plcsourcepro.com\/products\/150-f60nbdb-industrial-automation-module-by-allen-bradley","provider":"PLC Source PRO","version":"1.0","type":"link"}