{"product_id":"flexem-f5-md0808n-industrial-automation-module-heavy-duty","title":"Flexem F5-MD0808N Industrial Automation Module - Heavy-Duty","description":"\u003ch2\u003eProduct Introduction\u003c\/h2\u003e\u003cp\u003eThe Flexem F5-MD0808N Industrial Automation Module is a compact, high-performance I\/O module designed for demanding control applications. It combines 8 bipolar input channels with 8 transistor output channels, all in a single unit. Whether you’re upgrading an existing PLC or building a new control panel, the F5-MD0808N delivers reliable performance with precise 24 VDC operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cp\u003eBelow are the key specifications for the Flexem F5-MD0808N, detailed for engineering reference.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e8 (Bipolar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0~28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Peak Voltage\u003c\/td\u003e\n\u003ctd\u003e30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current (max)\u003c\/td\u003e\n\u003ctd\u003e9 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON State Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;15V (15~28.8V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF State Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5V (0~5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON State Current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF State Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptocoupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e3.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Time\u003c\/td\u003e\n\u003ctd\u003eDefault 1 ms; 16 levels selectable (unfiltered to 100 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e2\/3-wire sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eSource\/sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Length\u003c\/td\u003e\n\u003ctd\u003eShielded: 100 m; Unshielded: 50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e30V max, limited to 1 hour\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e8 (Transistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2~28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Group\u003c\/td\u003e\n\u003ctd\u003e0.5 A × output points per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (off)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Lamp Power\u003c\/td\u003e\n\u003ctd\u003e2.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDerating\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart Time (max)\u003c\/td\u003e\n\u003ctd\u003e34 μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-off Time (max)\u003c\/td\u003e\n\u003ctd\u003e250 μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Frequency\u003c\/td\u003e\n\u003ctd\u003e1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Short-circuit Current\u003c\/td\u003e\n\u003ctd\u003e1.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-recovery Time\u003c\/td\u003e\n\u003ctd\u003ePer 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamping Voltage\u003c\/td\u003e\n\u003ctd\u003eMax 39 VDC, ±1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (output)\u003c\/td\u003e\n\u003ctd\u003e500 V AC (output vs internal logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Cable Type\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Cable Length\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe Flexem F5-MD0808N excels in automation environments where mixed signal handling is essential. Its 8 bipolar inputs accept both source and sinking signals, making it ideal for integrating diverse sensors such as proximity switches and photoelectric sensors. The transistor outputs can drive small loads like indicator lamps, relays, or solenoid valves directly. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePackaging machinery control systems\u003c\/li\u003e\n\u003cli\u003eMaterial handling and conveyor systems\u003c\/li\u003e\n\u003cli\u003eProcess control panels in chemical or food industries\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWith a maximum output frequency of 1 kHz, the F5-MD0808N handles high-speed switching tasks with ease, reducing downtime and improving throughput.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eMount the Flexem F5-MD0808N on a standard DIN rail in a clean, dry enclosure. Ensure adequate clearance for ventilation. For wiring, use shielded cable up to 100 meters for inputs to minimize electromagnetic interference; for outputs, unshielded cable up to 50 meters is acceptable. Verify that the supply voltage stays within 19.2~28.8 VDC for outputs and 0~28.8 VDC for inputs. After wiring, power up and check the status LEDs (if present) to confirm proper operation.\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eThe F5-MD0808N is designed for long-term reliability with no derating required. Overvoltage protection limits input peaks to 30V, and short circuit protection on outputs prevents damage from wiring faults. To ensure consistent performance, periodically inspect terminal connections for tightness and check for dust accumulation on the module. With proper care, this module provides years of trouble-free service, minimizing replacement costs and downtime.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore purchasing the Flexem F5-MD0808N, confirm that your system’s voltage requirements and sensor types match the module’s specifications. Verify the input type (source\/sinking) and output load requirements. PLC Source PRO offers genuine Flexem F5-MD0808N modules with fast shipping and a reliable warranty. Contact our experts for assistance in selecting the right I\/O module for your application.\u003c\/p\u003e","brand":"Flexem","offers":[{"title":"Default","offer_id":44444500983907,"sku":"F5-MD0808N","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/F5-MD0808N.jpg?v=1785933341","url":"https:\/\/www.plcsourcepro.com\/he\/products\/flexem-f5-md0808n-industrial-automation-module-heavy-duty","provider":"PLC Source PRO","version":"1.0","type":"link"}