{"product_id":"bently-nevada-330101-12-40-10-02-cn-industrial-automation-module","title":"Bently Nevada 330101-12-40-10-02-CN Industrial Automation Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Bently Nevada 330101-12-40-10-02-CN is a 3300 XL 8 mm Probe designed for precise vibration and displacement monitoring in critical rotating machinery. With a 3\/8-24 UNF thread and no armor, this probe delivers reliable performance in demanding industrial environments. The 330101-12-40-10-02-CN features a total length of 1.0 meter (3.3 feet), an unthreaded length of 1.2 inches, and an overall case length of 4.0 inches. It includes a miniature coaxial ClickLoc connector with standard cable, ensuring secure and straightforward installation.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented TipLoc molding\u003c\/strong\u003e for a robust bond between probe tip and body.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented CableLoc design\u003c\/strong\u003e provides 330 N (75 lbf) pull strength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional FluidLoc cable option\u003c\/strong\u003e prevents oil or liquid leakage through the cable interior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThicker PPS encapsulation\u003c\/strong\u003e in the probe tip for enhanced ruggedness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel case\u003c\/strong\u003e (AISI 303 or 304) for durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e from -52°C to +177°C (standard probe).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e1.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e4.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Probe DC Resistance (1.0 m)\u003c\/td\u003e\n\u003ctd\u003e7.59 ± 0.50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils) from 0.25 to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e-9 Vdc (approximately 1.27 mm \/ 50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF) – Standard 5 or 1 meter system\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL) – Standard 5 or 1 meter system\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.025 mm (±1 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Weight\u003c\/td\u003e\n\u003ctd\u003e323 g\/m (11.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\/Storage Temperature (Standard)\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3% change in ASF at 93% humidity per IEC 68-2-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe Bently Nevada 330101-12-40-10-02-CN is ideal for monitoring radial vibration and shaft displacement in turbomachinery, compressors, pumps, and motors. Its robust design and high accuracy make it suitable for predictive maintenance programs. In a typical application, the probe is mounted through a machine casing to measure shaft vibration relative to the bearing housing, enabling early detection of issues like unbalance, misalignment, or bearing wear. The 330101-12-40-10-02-CN delivers reliable data for condition monitoring systems, helping reduce unplanned downtime.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup\u003c\/h2\u003e\u003cp\u003eFor optimal performance, mount the probe with the recommended gap setting of -9 Vdc, corresponding to approximately 1.27 mm (50 mils) from the target. Ensure the probe tip is clean and free from debris. Use the specified field wiring: 0.2 to 1.5 mm² (16 to 24 AWG), preferably a 3-conductor shielded triad cable with tinned conductors. Maintain a maximum cable length of 305 meters (1,000 feet) between the Proximitor Sensor and the monitor to avoid signal degradation. Secure the connector using the ClickLoc mechanism to prevent loosening.\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eThe 330101-12-40-10-02-CN is designed for long-term reliability. Its stainless steel case and PPS tip resist harsh environments. Regularly inspect the probe cable and connector for wear or damage. The patented CableLoc design provides 330 N (75 lbf) pull strength, reducing the risk of cable detachment. If the probe is exposed to temperatures below -34°C (-30°F), the pressure seal may fail prematurely, so avoid such conditions. For applications with high humidity, the probe maintains stable performance with less than 3% change in Average Scale Factor.\u003c\/p\u003e\u003ch2\u003eSelection Guide\u003c\/h2\u003e\u003cp\u003eWhen ordering the Bently Nevada 330101-12-40-10-02-CN, verify the thread type (3\/8-24 UNF) and the absence of armor to match your installation requirements. Confirm the total length and connector type (miniature coaxial ClickLoc) fit your system. Ensure the probe's temperature range aligns with your operating environment. For assistance with compatibility or to place an order, contact PLC Source PRO, your trusted supplier of industrial automation parts.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default","offer_id":44482001338467,"sku":"330101-12-40-10-02-CN","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/330101-00-08-20-12-05_ab170a35-9a7d-4cba-95a3-c86ccef69f30.jpg?v=1786779730","url":"https:\/\/www.plcsourcepro.com\/he\/products\/bently-nevada-330101-12-40-10-02-cn-industrial-automation-module","provider":"PLC Source PRO","version":"1.0","type":"link"}