{"product_id":"bently-nevada-330101-00-12-10-12-industrial-automation-module","title":"Bently Nevada 330101-00-12-10-12 Industrial Automation Module","description":"\u003cp\u003eManufacturer : Bently Nevada\u003c\/p\u003e\u003cp\u003eProduct No. : 330101-00-12-10-12\u003c\/p\u003e\u003cp\u003eProduct Type : 3300 XL 8 mm Probe, 3\/8-24 UNF thread,\u003cbr\u003ewithout armor\u003c\/p\u003e\u003cp\u003eMade in U.S.A\u003c\/p\u003e\u003cp\u003e330101 - 3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/p\u003e\u003cp\u003eUnthreaded Length Option : 00 - 0.0 in\u003c\/p\u003e\u003cp\u003eOverall Case Length Option : 12 - 1.2 in\u003c\/p\u003e\u003cp\u003eTotal Length Option : 10 - 1.0 metre (3.3 feet)\u003c\/p\u003e\u003cp\u003eConnector and Cable-Type Option : 12 Miniature coaxial ClickLoc\u003cbr\u003econnector, FluidLoc cable\u003c\/p\u003e\u003cp\u003eCN - Agency Approval Option : Approvals country specific\u003c\/p\u003e\u003cp\u003eThe 3300 XL probe and extension cable also\u003cbr\u003ereflect improvements over previous designs. A\u003cbr\u003epatented TipLoc molding method provides a\u003cbr\u003emore robust bond between the probe tip and\u003cbr\u003ethe probe body. The probe’s cable incorporates\u003cbr\u003ea patented CableLoc design that provides 330\u003cbr\u003eN (75 lbf) pull strength to more securely attach\u003cbr\u003ethe probe cable and probe tip.\u003cbr\u003eYou can also order 3300 XL 8 mm probes and\u003cbr\u003eextension cables with an optional FluidLoc\u003cbr\u003ecable option. This option prevents oil and other\u003cbr\u003eliquids from leaking out of the machine through\u003cbr\u003ethe cable’s interior.\u003c\/p\u003e\u003cp\u003e8 mm probes provide\u003cbr\u003ea thicker encapsulation\u003cbr\u003eof the probe coil in the molded PPS plastic\u003cbr\u003eprobe tip. This results in\u003cbr\u003ea more rugged probe.\u003cbr\u003eThe larger diameter of the probe body also\u003cbr\u003eprovides\u003cbr\u003ea stronger, more robust case. We\u003cbr\u003erecommend that you use\u003cbr\u003e8 mm probes when\u003cbr\u003epossible to provide optimal robustness against\u003cbr\u003ephysical abuse\u003c\/p\u003e\u003cp\u003eNominal Probe DC Resistance\u003cbr\u003eResistance (RPROBE) from Center Conductor\u003cbr\u003eto Outer Conductor\u003cbr\u003eProbe\u003cbr\u003eLength (m)\u003cbr\u003eRPROBE(Ω)\u003c\/p\u003e\u003cp\u003e1.0 7.59 ± 0.50\u003c\/p\u003e\u003cp\u003eExtension Cable\u003cbr\u003eCapacitance\u003cbr\u003e69.9 pF\/m (21.3 pF\/ft)\u003cbr\u003etypical\u003cbr\u003eField Wiring\u003cbr\u003e0.2 to 1.5 mm2 (16 to 24\u003cbr\u003eAWG). Recommend using\u003cbr\u003e3 conductor shielded triad\u003cbr\u003ecable and tinned field\u003cbr\u003ewiring. Maximum length of\u003cbr\u003e305 meters (1,000 feet)\u003cbr\u003ebetween the 3300 XL\u003cbr\u003eProximitor Sensor and the\u003cbr\u003emonitor. See the frequency\u003cbr\u003eresponse graphs, Figures\u003cbr\u003e10 and 12, for signal rolloff\u003cbr\u003eat high frequencies when\u003cbr\u003eusing longer field wiring\u003cbr\u003elengths.\u003cbr\u003eLinear Range\u003cbr\u003e2 mm (80 mils). Linear\u003cbr\u003erange begins at\u003cbr\u003eapproximately 0.25 mm (10\u003cbr\u003emils) from target and is\u003cbr\u003efrom 0.25 to 2.3 mm (10 to\u003cbr\u003e90 mils) (approximately –1\u003cbr\u003eto –17 Vdc).\u003cbr\u003eRecommended\u003cbr\u003eGap Setting for\u003cbr\u003eRadial Vibration\u003cbr\u003e-9 Vdc [approximately 1.27\u003cbr\u003emm (50 mils)]\u003cbr\u003eIncremental Scale Factor (ISF)\u003cbr\u003eStandard 5 or 1\u003cbr\u003emeter System\u003cbr\u003e7.87 V\/mm (200 mV\/mil) ±\u003cbr\u003e5% including\u003cbr\u003einterchangeability error\u003cbr\u003ewhen measured in\u003cbr\u003eincrements of 0.25 mm (10\u003cbr\u003emils) over the 80 mil linear\u003cbr\u003erange from 0°C to +45°C\u003cbr\u003e(+32°F to +113°F).\u003cbr\u003eStandard 9\u003cbr\u003emeter System\u003cbr\u003e7.87 V\/mm (200 mV\/mil)\u003cbr\u003e± 6.5% including\u003cbr\u003einterchangeability error\u003cbr\u003ewhen measured in\u003cbr\u003eincrements of 0.25 mm (10\u003cbr\u003emils) over the 80 mil linear\u003cbr\u003erange from 0°C to +45°C\u003cbr\u003e(+32°F to +113°F).\u003cbr\u003eExtended\u003cbr\u003eTemperature\u003cbr\u003eRange (ETR) for 5\u003cbr\u003eand 9 Meter\u003cbr\u003eSystems\u003cbr\u003e7.87 V\/mm (200 mV\/mil) ±\u003cbr\u003e6.5% including\u003cbr\u003einterchangeability error\u003cbr\u003ewhen measured in\u003cbr\u003eincrements of 0.25 mm (10\u003cbr\u003emils) over the 80 mil linear\u003cbr\u003erange from 0°C to +45°C\u003cbr\u003e(+32°F to +113°F).\u003cbr\u003eDeviation from best fit straight line (DSL)\u003cbr\u003eStandard 5 or 1\u003cbr\u003emeter System\u003cbr\u003eLess than ±0.025 mm (±1\u003cbr\u003emil) with components at\u003cbr\u003e0°C to +45°C (+32°F to\u003cbr\u003e+113°F).\u003cbr\u003eStandard 9\u003cbr\u003emeter System\u003cbr\u003eLess than ±0.038 mm (±1.5\u003cbr\u003emil) with components at\u003cbr\u003e0°C to +45°C (+32°F to\u003cbr\u003e+113°F).\u003cbr\u003eExtended\u003cbr\u003eTemperature\u003cbr\u003eRange 5 and 9\u003cbr\u003emeter Systems\u003cbr\u003eLess than ±0.038 mm (±1.5\u003cbr\u003emil) with components at\u003cbr\u003e0°C to +45°C (+32°F to\u003cbr\u003e+113°F).\u003c\/p\u003e\u003cp\u003eProbe Tip\u003cbr\u003eMaterial Polyphenylene sulfide (PPS).\u003cbr\u003eProbe Case\u003cbr\u003eMaterial\u003cbr\u003eAISI 303 or 304 stainless steel\u003cbr\u003e(SST).\u003c\/p\u003e\u003cp\u003e323 g\/m (11.4 oz)\u003c\/p\u003e\u003cp\u003eProbe Temperature Range\u003cbr\u003eOperating and Storage Temperature\u003cbr\u003eStandard\u003cbr\u003eProbe\u003cbr\u003e-52°C to +177°C (-62°F to\u003cbr\u003e+350°F)\u003cbr\u003eExtended\u003cbr\u003eTemperature\u003cbr\u003eRange Probe\u003cbr\u003e-52°C to +218°C (-62°F to\u003cbr\u003e+425°F) for the probe tip; -\u003cbr\u003e51°C to +260°C (-60°F to\u003cbr\u003e+500°F) for the probe cable\u003cbr\u003eand connector.\u003cbr\u003eExposing the probe to temperatures\u003cbr\u003ebelow –34˚C (-30˚F) may cause\u003cbr\u003epremature failure of the pressure\u003cbr\u003eseal.\u003c\/p\u003e\u003cp\u003eProbe Pressure\u003cbr\u003e 3300 XL 8 mm probes are designed to seal\u003cbr\u003edifferential pressure between the probe tip\u003cbr\u003eand case. The probe sealing material consists\u003cbr\u003eof a Viton® O ring. Probes are not pressure\u003cbr\u003etested prior to shipment. Contact our custom\u003cbr\u003edesign department if you require a test of the\u003cbr\u003epressure seal for your application.\u003c\/p\u003e\u003cp\u003eProbe Relative Humidity\u003cbr\u003eLess than a 3% change in Average Scale\u003cbr\u003eFactor (ASF) when tested in 93% humidity in\u003cbr\u003eaccordance with IEC standard 68 2 3 for up to\u003cbr\u003e56 days.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default","offer_id":50524212723811,"sku":"330101-00-12-10-12","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/330101-00-08-20-12-05_2545fd61-3d4c-406a-8cc2-779b5620ebd7.jpg?v=1790246164","url":"https:\/\/www.plcsourcepro.com\/he\/products\/bently-nevada-330101-00-12-10-12-industrial-automation-module","provider":"PLC Source PRO","version":"1.0","type":"link"}