{"product_id":"abb-ci871a-ac-800m-profinet-io-communication-interface-module","title":"ABB CI871A AC 800M PROFINET IO Communication Interface Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe ABB CI871A is a high-performance communication interface designed for the AC 800M controller family. It enables seamless connectivity to PROFINET IO devices over Ethernet, making it an essential component for modern industrial automation systems. With support for System 800xA 6.0.3.3, 6.1.1, and subsequent versions, the CI871A ensures reliable data exchange in demanding process control environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cp\u003eThe ABB CI871A module delivers robust performance with the following key parameters:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE092693R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster\/Slave\u003c\/td\u003e\n\u003ctd\u003eMaster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with HI Controller\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Units on CEX Bus\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRJ-45 female (8-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V Consumption (typ.)\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 °C (+41 to +131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C (-40 to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (IEC\/EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2 (IEC\/EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3 (ISA 71.04)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 (EN60529, IEC 529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eUL 61010-1, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eUL 60079-15, cULus Class 1, Zone 2, AEx nA IIC T4, ExnA IIC T4Gc X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd\u003eDNV-GL (Pending: ABS, BV, LR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2011\/65\/EU (EN 50581:2012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm (2.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e185 mm (7.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm (5.0 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (incl. base)\u003c\/td\u003e\n\u003ctd\u003e700 g (1.5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET IO Master:\u003c\/strong\u003e The CI871A acts as a master, controlling up to 12 devices on the CEX bus, ensuring efficient data acquisition and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Connectivity:\u003c\/strong\u003e Supports 10\/100 Mbit\/s transmission speeds, providing fast and reliable communication for time-critical processes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swap Capability:\u003c\/strong\u003e Enables module replacement without system shutdown, minimizing downtime and improving maintenance efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Module redundancy ensures continuous operation even if one module fails, enhancing system availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Environmental Tolerance:\u003c\/strong\u003e Operates in temperatures from +5 to +55 °C and withstands harsh conditions, including G3 corrosion environments and hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eTo install the ABB CI871A, mount it on the TP867 Baseplate. The baseplate provides two RJ45 Ethernet connectors; use only the CH1 connector for PROFINET IO connection, as it supports 100 Mbps. Connect the Ethernet cable from CH1 to an Ethernet switch that links to the PROFINET IO network. Ensure the module is properly seated on the CEX bus and that the 24 V supply is connected. Verify that the System 800xA version is 6.0.3.3 or later before powering up.\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eRegularly inspect the Ethernet connections and the RJ45 connectors for dust or damage. Check the module's status LEDs for any fault indications. Keep the ambient temperature within the specified range (+5 to +55 °C) to prevent overheating. The CI871A's hot-swap feature allows for quick replacement during maintenance, reducing operational downtime. Periodic firmware updates, if available, can enhance performance and security.\u003c\/p\u003e\u003ch2\u003eCompatibility \u0026amp; Integration\u003c\/h2\u003e\u003cp\u003eThe ABB CI871A is designed for use with the AC 800M controller and is compatible with System 800xA versions 6.0.3.3, 6.1.1, and later. It integrates seamlessly with PROFINET IO networks, enabling communication with a wide range of PROFINET devices. The module supports both module redundancy and hot swap, making it suitable for high-availability applications. It works with HI Controllers, ensuring robust performance in critical control loops.\u003c\/p\u003e\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\u003cp\u003eThe ABB CI871A is ideal for industries requiring reliable PROFINET communication, such as:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Connect field devices like valve positioners and transmitters to the AC 800M controller in chemical or pharmaceutical plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing:\u003c\/strong\u003e Integrate PLCs, drives, and sensors on a production line for synchronized operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilities:\u003c\/strong\u003e Monitor and control water treatment or power generation equipment with high-speed data exchange.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIn each scenario, the CI871A ensures deterministic communication, reducing signal delays and improving process accuracy.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore purchasing the ABB CI871A, verify your system compatibility: ensure your controller is an AC 800M and your System 800xA version is 6.0.3.3 or later. Confirm that your network infrastructure includes an Ethernet switch for PROFINET IO. For assistance with product selection or technical questions, contact PLC Source PRO — your trusted supplier for genuine industrial automation parts.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default","offer_id":44443322220643,"sku":"CI871A","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/CI871A.jpg?v=1785927625","url":"https:\/\/www.plcsourcepro.com\/he\/products\/abb-ci871a-ac-800m-profinet-io-communication-interface-module","provider":"PLC Source PRO","version":"1.0","type":"link"}