{"product_id":"abb-ao810-industrial-automation-module-industrial-grade","title":"ABB AO810 Industrial Automation Module - Industrial-Grade","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe ABB AO810 analog output module (Article No. 3BSE038415R1) delivers eight unipolar analog output channels engineered for precision and reliability in demanding industrial environments. This S800 series module performs cyclic self-diagnostics, including readback verification of serial data to the D\/A converters and open-circuit detection. When output supply voltage drops too low, the AO810 reports a module error; channel faults (open circuit for currents above 1 mA) are flagged only on active channels. With its robust design and comprehensive supervision, the AO810 ensures dependable performance in process control and automation systems.\u003c\/p\u003e\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e8 channels supporting 0...20 mA and 4...20 mA output signals\u003c\/li\u003e\n\u003cli\u003eOutputs set to a predetermined state (OSP) upon error detection for fail-safe operation\u003c\/li\u003e\n\u003cli\u003eShort-circuit protected outputs to ZP or +24 V\u003c\/li\u003e\n\u003cli\u003eReadback and verification of serial communication to D\/A converters\u003c\/li\u003e\n\u003cli\u003eCyclic self-diagnostics with process power supply supervision\u003c\/li\u003e\n\u003cli\u003eCompatible with TU810V1 mounting unit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE038415R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e0..20 mA, 4..20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGroupwise isolated from ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnder\/Over Range\u003c\/td\u003e\n\u003ctd\u003e- \/ +15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e≤ 500 Ω (supply connected to L1+ only); 250 - 850 Ω (with supply connected L2+ only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003eMax. 0.1% at 0 - 500 ohms (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003eTyp. 30 ppm\/°C, Max 60 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e0.35 ms (PL = 500 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Cycle Time\u003c\/td\u003e\n\u003ctd\u003e≤ 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003eShort circuit proof current limited output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 meters (656 yards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V a.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +5 V Modulebus\u003c\/td\u003e\n\u003ctd\u003eMax 70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V Modulebus\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption +24 V external\u003c\/td\u003e\n\u003ctd\u003e245 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront LEDs\u003c\/td\u003e\n\u003ctd\u003eF(ault), R(un), W(arning), O(SP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupervision\u003c\/td\u003e\n\u003ctd\u003eModule Error: Output power low; Channel Error: Open circuit (for current \u0026gt;1 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eModule Error, Module Warning, Channel Error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 °C (+32 to +131 °F); approvals issued for +5 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C (-40 to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e55 °C (131 °F); for vertical mounting in compact MTU 40 °C (104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Operating Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4 and EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Categories\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60664-1, EN 50178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eClass I according to IEC 61140 (earth protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eDIRECTIVE\/2011\/65\/EU (EN 50581:2012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDIRECTIVE\/2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eMTU TU810, TU812, TU814, TU830, TU833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eAE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e45 mm (1.77”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e102 mm (4.01”), 111 mm (4.37”) including connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e119 mm (4.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg (0.4 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ABB AO810 analog output module excels in process control systems where precise current loop outputs are critical. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Positioning:\u003c\/strong\u003e Controlling 4-20 mA signals to position pneumatic or electric valves in chemical plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable Frequency Drives:\u003c\/strong\u003e Sending speed setpoints to VFDs in conveyor systems and pump stations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePID Loop Control:\u003c\/strong\u003e Providing analog output for closed-loop control in temperature or flow systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor example, in a water treatment facility, the AO810 can drive multiple dosing pumps while its open-circuit diagnostics immediately alert operators to a broken wire, minimizing chemical waste and downtime.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup\u003c\/h2\u003e\u003cp\u003eMount the AO810 in a compatible S800 series I\/O chassis. Ensure proper keying (code AE) before insertion. Connect output wiring to the appropriate terminals on the TU810V1 mounting unit. For optimal performance, keep field cable lengths under 600 meters. When connecting loads, verify the supply configuration: if using L1+ only, the load must not exceed 500 Ω; with L2+ supply, loads from 250 to 850 Ω are supported. After installation, perform a loop check to confirm output current matches the setpoint.\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eRoutine maintenance is minimal due to the AO810's solid-state design. Periodically inspect cables and connectors for wear or corrosion, especially in harsh environments (the module meets ISA-S71.04 G3 corrosion protection). The module's self-diagnostics and front LEDs (F, R, W, OSP) provide immediate status indication, reducing troubleshooting time. With a power dissipation of only 2.3 W, the AO810 runs cool, extending component life. Its wide operating temperature range (-40 to +70 °C storage) ensures reliability in extreme conditions.\u003c\/p\u003e\u003ch2\u003eCompatibility \u0026amp; Integration\u003c\/h2\u003e\u003cp\u003eThe AO810 integrates seamlessly into ABB S800 I\/O systems. It works with MTU models TU810, TU812, TU814, TU830, and TU833, and is specifically matched with the TU810V1. This module supports 0-20 mA and 4-20 mA signals, making it versatile for various PLC and DCS platforms. Its groupwise isolation from ground helps prevent ground loops in complex installations. For redundancy or high-integrity applications, note that this module does not support HART, SOE, redundancy, or high-integrity configurations.\u003c\/p\u003e\u003ch2\u003eBuying Guide\u003c\/h2\u003e\u003cp\u003eBefore purchasing, verify your system's compatibility with the AO810 (Article No. 3BSE038415R1). Confirm the required number of channels and output signal types. If you need HART or redundancy, consider other modules. When sourcing, choose a trusted supplier like PLC Source PRO to ensure genuine parts and reliable support. Always check the module's keying code (AE) matches your rack.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default","offer_id":44442928545891,"sku":"AO810","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/AO810V2.jpg?v=1785924718","url":"https:\/\/www.plcsourcepro.com\/he\/products\/abb-ao810-industrial-automation-module-industrial-grade","provider":"PLC Source PRO","version":"1.0","type":"link"}