{"product_id":"1756-a13-industrial-automation-module-by-allen-bradley","title":"1756-A13 Industrial Automation Module by Allen-Bradley","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eWhen your control system needs a reliable foundation for up to thirteen modules, the Allen-Bradley 1756-A13 13-slot ControlLogix chassis delivers the structural and electrical backbone required for demanding industrial environments. This chassis provides a high-speed communication path between modules and distributes power to each installed module, ensuring stable operation of your ControlLogix controllers and I\/O modules.\u003c\/p\u003e\u003cp\u003eThe 1756-A13 is designed for horizontal mounting only, which simplifies panel layout and cable routing. With its open enclosure rating, it is intended for installation within a suitable cabinet that meets the minimum size requirement of 762 x 609 x 203 mm (30 x 24 x 8 in.). The chassis features eight mounting tabs for secure attachment to the subpanel.\u003c\/p\u003e\u003cp\u003eEvery ControlLogix module can be placed into any of the 13 slots, offering maximum flexibility in system configuration. To maintain proper airflow and cooling, empty slots must be filled with 1756-N2 slot filler modules.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cp\u003eThe following table lists the key technical parameters for the Allen-Bradley 1756-A13 chassis. These values are critical for system design and integration.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1756-A13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eChassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current @ 1.2 VDC\u003c\/td\u003e\n\u003ctd\u003e1.5 A (chassis\/slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current @ 3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e4 A \/ 4 A (chassis\/slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current @ 5.1 VDC\u003c\/td\u003e\n\u003ctd\u003e15 A \/ 6 A (chassis\/slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current @ 24 VDC\u003c\/td\u003e\n\u003ctd\u003e2.8 A \/ 2.8 A (chassis\/slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation (Max)\u003c\/td\u003e\n\u003ctd\u003e5.4 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e588 x 169 x 145 mm (23.15 x 6.65 x 5.71 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.90 kg (4.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Tabs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Series B)\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C (+32°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Series C)\u003c\/td\u003e\n\u003ctd\u003e-25°C to +60°C (-13°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e10612598129284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNSPSC\u003c\/td\u003e\n\u003ctd\u003e32151704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe Allen-Bradley 1756-A13 chassis is a versatile backbone for a wide range of industrial automation applications. Its 13-slot capacity allows for a mix of controllers, communication modules, and I\/O cards, making it ideal for:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Manufacturing:\u003c\/strong\u003e Control assembly lines, packaging machinery, and material handling systems with high-speed I\/O and logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Control:\u003c\/strong\u003e Manage continuous processes such as chemical production, oil refining, or water treatment, where reliable backplane communication is essential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrastructure:\u003c\/strong\u003e Monitor and control power distribution, HVAC, or building automation systems, leveraging the chassis's robust design and environmental tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBecause any ControlLogix module can be placed in any slot, the 1756-A13 adapts to evolving system requirements without hardware changes.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eProper installation ensures optimal performance and longevity of the 1756-A13 chassis. Follow these guidelines:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMount the chassis horizontally on the subpanel using the eight provided mounting tabs. Ensure the cabinet meets the minimum size of 762 x 609 x 203 mm (30 x 24 x 8 in.).\u003c\/li\u003e\n\u003cli\u003eConnect the functional earth ground using 8.3 mm² (8 AWG) solid or stranded copper wire rated at 90°C (194°F) or greater. Use 2.1 mm² (14 AWG) wire for protective earth ground, also rated at 90°C or greater.\u003c\/li\u003e\n\u003cli\u003eInstall 1756-N2 slot filler modules in any empty slots to maintain proper cooling and prevent dust ingress.\u003c\/li\u003e\n\u003cli\u003eFor field wiring, use a Bulletin 1492 Interface Module (IFM) or a Removable Terminal Block (RTB) to connect field-side wiring to I\/O modules.\u003c\/li\u003e\n\u003cli\u003eVerify that the ambient temperature remains within the operating range for your chassis series (Series B: 0°C to +60°C; Series C: -25°C to +60°C).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eThe 1756-A13 chassis is designed for long service life with minimal maintenance. Routine checks should include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInspecting mounting hardware for tightness and signs of corrosion.\u003c\/li\u003e\n\u003cli\u003eCleaning the chassis and backplane connections from dust or debris using appropriate methods.\u003c\/li\u003e\n\u003cli\u003eVerifying that all slot filler modules remain in place to maintain airflow.\u003c\/li\u003e\n\u003cli\u003eMonitoring ambient temperature and humidity to stay within specified limits (5% to 95% relative humidity, non-condensing).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThanks to the Removal and Insertion Under Power (RIUP) feature, modules can be replaced without powering down the system, minimizing downtime and improving overall equipment effectiveness.\u003c\/p\u003e\u003ch2\u003eCompatibility \u0026amp; Integration\u003c\/h2\u003e\u003cp\u003eThe Allen-Bradley 1756-A13 is part of the ControlLogix family and is compatible with a wide range of Rockwell Automation controllers, including the Logix 5560, 5570, and 5580 product families. It supports all ControlLogix communication modules and I\/O modules, allowing seamless integration into existing or new automation architectures.\u003c\/p\u003e\u003cp\u003eThe chassis provides electronic keying to prevent incorrect module insertion, reducing commissioning errors and protecting your investment.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore purchasing the 1756-A13, verify that your application requires a 13-slot chassis and that your cabinet space meets the minimum dimensions. Consider the backplane current requirements of your modules to ensure they do not exceed the chassis's limits.\u003c\/p\u003e\u003cp\u003ePLC Source PRO offers genuine Allen-Bradley 1756-A13 chassis with reliable availability. Contact our team for assistance in selecting the right chassis for your system.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default","offer_id":44434854150243,"sku":"1756-A13","price":224.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/1756-2WS_afc45eec-0ff7-4591-ba36-ecfc7deee38a.jpg?v=1785775766","url":"https:\/\/www.plcsourcepro.com\/he\/products\/1756-a13-industrial-automation-module-by-allen-bradley","provider":"PLC Source PRO","version":"1.0","type":"link"}