{"product_id":"150-f625nbeb-industrial-automation-module-by-allen-bradley","title":"150-F625NBEB Industrial Automation Module by Allen-Bradley","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Allen-Bradley 150-F625NBEB is a Bulletin 150 SMC-Flex solid-state smart motor controller designed for demanding industrial applications. With a robust 625 A rating and support for motors up to 500 Hp @ 460V AC, this open-type controller delivers precise, reliable motor starting and stopping. Its pump control option makes it ideal for pump applications where smooth acceleration and deceleration reduce water hammer and mechanical stress.\u003c\/p\u003e\u003cp\u003eThis controller accepts input voltages from 200 to 480V AC (3-phase, 50\/60 Hz) and uses a 100...120V AC control supply. The SMC-Flex platform offers advanced features such as integrated motor overload protection, adjustable trip classes, and optional SMB smart motor braking—all in a single, compact unit.\u003c\/p\u003e\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Power Handling:\u003c\/strong\u003e 625 A continuous current, 500 Hp @ 460V AC, with line-connected motor power up to 800 Hp @ 600V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Control Options:\u003c\/strong\u003e Pump control option for soft start\/stop, reducing surge pressures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Protection:\u003c\/strong\u003e Built-in motor overload protection, PTC sensor inputs, and DV\/DT protection via RC snubber network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Trip Classes:\u003c\/strong\u003e Selectable trip classes 10, 15, 20, and 30 to match application needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Smart Braking:\u003c\/strong\u003e SMB feature provides adjustable braking current from 0...400% of motor FLC without extra equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e Heatsink hockey puck thyristor design, IP00 protection, and wide operating temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eBulletin 150, Solid State Controller (Soft Starter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Line Voltage\u003c\/td\u003e\n\u003ctd\u003e200...480V AC, 3-Phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e100...120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage (Ue)\u003c\/td\u003e\n\u003ctd\u003e200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Control Supply Voltage (AC 50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Rating\u003c\/td\u003e\n\u003ctd\u003e625 A, 500 Hp @ 460V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connected Motor Current\u003c\/td\u003e\n\u003ctd\u003e208...625 A @ 600\/Y\/690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelta Connected Motor Current\u003c\/td\u003e\n\u003ctd\u003e283...850 A @ 500\/575V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Current (Line Connected)\u003c\/td\u003e\n\u003ctd\u003e208 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Current (Delta Connected)\u003c\/td\u003e\n\u003ctd\u003e283 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Classes\u003c\/td\u003e\n\u003ctd\u003e10, 15, 20, 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Current Rating\u003c\/td\u003e\n\u003ctd\u003e117% of motor FLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motor Overload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeatsink Fan Rating\u003c\/td\u003e\n\u003ctd\u003e150 VA @ 110\/120V AC or 220\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDV\/DT Protection\u003c\/td\u003e\n\u003ctd\u003eRC snubber network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepetitive Peak Inverse Voltage\u003c\/td\u003e\n\u003ctd\u003e1400 V per UL\/CSA\/NEMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Connected Motor Power (Max)\u003c\/td\u003e\n\u003ctd\u003e800 Hp @ 600V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelta Connected Motor Power (Max)\u003c\/td\u003e\n\u003ctd\u003e900 Hp @ 575V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Voltage\u003c\/td\u003e\n\u003ctd\u003e6000 V per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Withstand\u003c\/td\u003e\n\u003ctd\u003e2500 V per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Protection\u003c\/td\u003e\n\u003ctd\u003eMetal oxide varistors (220 J, optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e200...480V AC (-15%, +10%) per UL\/CSA\/NEMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Fault Current (Standard)\u003c\/td\u003e\n\u003ctd\u003e70 kA @ 690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Fault Current (High Capacity)\u003c\/td\u003e\n\u003ctd\u003e74 kA @ 600V (with Class J\/L fuses)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection Device\u003c\/td\u003e\n\u003ctd\u003eType 1 (standard fuse, circuit breaker, high-capacity time-delay Class CC\/J\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Input OFF-state Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 mA AC, \u0026lt;3 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF-state Voltage (Max)\u003c\/td\u003e\n\u003ctd\u003e50V AC @ 10V DC\/12V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON-state Voltage (Min)\u003c\/td\u003e\n\u003ctd\u003e85V AC @ 19.2V DC\/20.4V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON-state Current\u003c\/td\u003e\n\u003ctd\u003e20 mA @ 120V AC \/ 40 mA @ 240V AC \/ 7.6 mA @ 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePTC Input Ratings\u003c\/td\u003e\n\u003ctd\u003eMax 6 sensors, 30V open, \u0026lt;7.5V @ 4 kΩ, 1500 Ω cold resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (PTC)\u003c\/td\u003e\n\u003ctd\u003e800 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTachometer Input\u003c\/td\u003e\n\u003ctd\u003e0...5V DC @ 4.5V DC = 100% Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003e1 (19\/20, 29\/30, 31\/32, 33\/34) – programmable NO\/NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current (Aux)\u003c\/td\u003e\n\u003ctd\u003e3 A @ 120V AC, 1.5 A @ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake\/Break Capacity (Aux)\u003c\/td\u003e\n\u003ctd\u003e3600 VA \/ 360 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e446 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 50 °C (23 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5...95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP00 (open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Emission\u003c\/td\u003e\n\u003ctd\u003eClass A (radiated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Immunity\u003c\/td\u003e\n\u003ctd\u003eSurge transient per EN\/IEC 60947-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e4 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1.0 G peak, 0.15 mm displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e596.9 mm (23.50 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e346.2 mm (13.63 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1041.1 mm (41 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e179 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIndustry Applications\u003c\/h2\u003e\u003cp\u003eThe 150-F625NBEB excels in pump, fan, and compressor applications where controlled acceleration and deceleration are critical. In water treatment plants, the pump control option reduces pressure surges, extending pipeline and valve life. In HVAC systems, it provides soft starting for large chillers and fans, minimizing electrical stress on the supply network.\u003c\/p\u003e\u003cp\u003eFor high-inertia loads like conveyors and crushers, the SMC-Flex controller ensures smooth, torque-controlled starts without mechanical shock. Its wide voltage range and high fault-current ratings make it suitable for heavy industrial environments.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup Guidance\u003c\/h2\u003e\u003cp\u003eMount the controller in a clean, well-ventilated area, respecting the IP00 open-type enclosure requirements. Ensure adequate clearance for airflow around the heatsink. Connect power wiring to the line and load terminals (two 13.5 mm diameter holes per pole) using appropriate lugs. For the control circuit, use the M3 screw clamp yoke connections. Set the trip class and PTC parameters according to motor data. Verify the control voltage (100...120V AC) and input supply before energizing.\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eRegularly inspect the cooling fan and heatsink for dust accumulation. Check torque on power terminals periodically. Monitor operating temperature and humidity (5...95% noncondensing). The RC snubber network protects against DV\/DT, but verify transient protection varistors if installed. With proper maintenance, the SMC-Flex provides years of reliable service.\u003c\/p\u003e\u003ch2\u003eSelection Guide \u0026amp; Purchasing Advice\u003c\/h2\u003e\u003cp\u003eBefore ordering, confirm your motor's full-load current (FLC) and line voltage. The 150-F625NBEB supports line-connected motors up to 625 A and delta-connected up to 850 A. Choose the appropriate short-circuit protection device (fuse or breaker) rated for the available fault current. For applications requiring fast stopping, consider the optional SMB braking feature. PLC Source PRO offers genuine Allen-Bradley 150-F625NBEB controllers with fast shipping and expert support.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default","offer_id":44434530435171,"sku":"150-F625NBEB","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/150-F625NBE-c1_7577043c-0e37-4206-83b1-3d932d58afae.jpg?v=1785756553","url":"https:\/\/www.plcsourcepro.com\/he\/products\/150-f625nbeb-industrial-automation-module-by-allen-bradley","provider":"PLC Source PRO","version":"1.0","type":"link"}