{"product_id":"flexem-f5-md1616r-industrial-automation-module-stable","title":"Flexem F5-MD1616R Industrial Automation Module - Stable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eIn demanding industrial environments, reliable signal acquisition and control are non-negotiable. The Flexem F5-MD1616R Industrial Automation Module delivers robust performance with its 16-point bipolar input and 16-point transistor output configuration. Designed for seamless integration into PLC and DCS systems, this module handles both digital inputs from sensors and outputs to actuators with precision. With a rated voltage of 24 VDC and an input range of 0~28.8V DC, the F5-MD1616R ensures stable operation across varying power conditions.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cp\u003eThe Flexem F5-MD1616R offers a comprehensive set of specifications that ensure reliable performance in industrial automation applications:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16-point bipolar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0~28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e7mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Peak Value\u003c\/td\u003e\n\u003ctd\u003e30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e9mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage in State 1\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;15V (15~28.8V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage in State 0\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5V (0~5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent in State 1\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent in State 0\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.0mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e3.3KΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Time\u003c\/td\u003e\n\u003ctd\u003eDefault 1ms, selectable from unfiltered to 100ms (16 levels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e2\/3-wire sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eSource\/sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Length\u003c\/td\u003e\n\u003ctd\u003e100m shielded, 50m unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e30V max, limited to 1 hour per day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2~28.8VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rated Current\u003c\/td\u003e\n\u003ctd\u003e0.5A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Group\u003c\/td\u003e\n\u003ctd\u003e0.5A per output point of each group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003eMax 1VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (Off)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Incandescent Lamp Power\u003c\/td\u003e\n\u003ctd\u003e2.4W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDerating\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart Time\u003c\/td\u003e\n\u003ctd\u003eMax 34μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-off Time\u003c\/td\u003e\n\u003ctd\u003eMax 250μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Frequency\u003c\/td\u003e\n\u003ctd\u003e1KHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Short-circuit Output Current\u003c\/td\u003e\n\u003ctd\u003e1.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-recovery After Short Circuit\u003c\/td\u003e\n\u003ctd\u003ePer 10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamping Voltage\u003c\/td\u003e\n\u003ctd\u003eMax 39VDC, ±1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Output)\u003c\/td\u003e\n\u003ctd\u003e500V AC between output and internal logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Channel Type\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Cable Length\u003c\/td\u003e\n\u003ctd\u003e50m unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003ePerformance and Reliability\u003c\/h2\u003e\u003cp\u003eThe Flexem F5-MD1616R incorporates fast switching times—start time of 34μs and turn-off time of 250μs—allowing for high-speed control loops. Its maximum output frequency of 1KHz suits applications requiring rapid actuation. Built-in short-circuit protection with peak current limiting at 1.3A and self-recovery every 10ms minimizes downtime and protects downstream equipment. The module's input filtering, adjustable from unfiltered to 100ms, helps reject electrical noise, ensuring stable readings in industrial environments.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe F5-MD1616R excels in various automation scenarios:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Control:\u003c\/strong\u003e Connect limit switches, proximity sensors, and push buttons to the inputs; drive relays and contactors via the outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor Systems:\u003c\/strong\u003e Monitor product presence and control motor starters with the high-speed outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Lines:\u003c\/strong\u003e Use the fast response times to synchronize labeling and sealing operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Interface with 2\/3-wire sensors to monitor temperature, pressure, or flow switches.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation and Wiring\u003c\/h2\u003e\u003cp\u003eProper installation ensures optimal performance. Mount the module on a standard DIN rail in a well-ventilated control cabinet. For inputs, use shielded cables up to 100m or unshielded up to 50m to maintain signal integrity. Connect sensors as source or sinking based on your system architecture. For outputs, unshielded cables up to 50m are acceptable; ensure correct polarity to avoid damage. The module supports both source and sinking input types, offering flexibility in wiring.\u003c\/p\u003e\u003ch2\u003eMaintenance and Troubleshooting\u003c\/h2\u003e\u003cp\u003eRoutine checks keep the F5-MD1616R operating reliably. Periodically verify that input voltages stay within 0~28.8V DC and output loads do not exceed 0.5A per point. Inspect cable connections for wear or corrosion. If a short circuit occurs, the module self-recovers within 10ms; persistent issues may indicate an external fault. Replace the module if damage is visible or if it fails to meet performance specs. The module's overvoltage protection limits exposure to 30V for a maximum of 1 hour per day—avoid prolonged overvoltage conditions.\u003c\/p\u003e\u003ch2\u003eWhy Choose PLC Source PRO?\u003c\/h2\u003e\u003cp\u003eWhen sourcing the Flexem F5-MD1616R, trust PLC Source PRO for genuine components and fast delivery. We specialize in industrial automation parts, ensuring you get the right module for your system. Contact our team for availability and pricing.\u003c\/p\u003e","brand":"Flexem","offers":[{"title":"Default","offer_id":44444719382627,"sku":"F5-MD1616R","price":278.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/F5-MD1616R-c1.jpg?v=1785933838","url":"https:\/\/www.plcsourcepro.com\/ar\/products\/flexem-f5-md1616r-industrial-automation-module-stable","provider":"PLC Source PRO","version":"1.0","type":"link"}