{"product_id":"abb-tb820v2-cluster-modem-i-o-module-3bse013208r1","title":"ABB TB820V2 Cluster Modem I\/O Module 3BSE013208R1","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe ABB TB820V2 Cluster Modem I\/O Module (3BSE013208R1) is a fiber optic interface that connects electrical and optical ModuleBus segments within the S800 I\/O system. It enables distributed I\/O clusters and supports up to seven clusters on the optical bus. When your process requires more than 12 I\/O modules per station, the TB820V2 provides a reliable, high-speed link between clusters and the parent controller.\u003c\/p\u003e\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo fiber optic ports for optical ModuleBus connectivity\u003c\/li\u003e\n\u003cli\u003eElectrical ModuleBus interface to up to 12 I\/O modules\u003c\/li\u003e\n\u003cli\u003eSupervisory functions for I\/O ModuleBus and power supply\u003c\/li\u003e\n\u003cli\u003eIsolated power supply to I\/O modules\u003c\/li\u003e\n\u003cli\u003eRotary switch selects cluster number (1–7) on the optical bus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle number\u003c\/td\u003e\n\u003ctd\u003e3BSE013208R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication protocol\u003c\/td\u003e\n\u003ctd\u003eModulebus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster or slave\u003c\/td\u003e\n\u003ctd\u003eSlave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed together with HI Controller\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V consumption (typ.)\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous location\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine certificates\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 °C (+32 to +131 °F); approvals issued for +5 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C (-40 to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax ambient temperature\u003c\/td\u003e\n\u003ctd\u003e55 °C (131 °F); for vertical mounting 40 °C (104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN60529, IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE compliance\u003c\/td\u003e\n\u003ctd\u003eDIRECTIVE\/2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e58 mm (2.39 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e170 mm (6.7 in.) including latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e122 mm (4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe ABB TB820V2 is ideal for process industries such as oil and gas, chemical, and power generation where distributed I\/O is required. Use it to extend your S800 I\/O network beyond the 12-module electrical limit, placing I\/O clusters near field devices while maintaining a single control strategy. Its fiber optic interface also provides electrical isolation and noise immunity, making it suitable for harsh industrial environments.\u003c\/p\u003e\u003ch2\u003eInstallation Guidance\u003c\/h2\u003e\u003cp\u003eMount the TB820V2 on a standard DIN rail in a suitable enclosure. Set the rotary switch to the desired cluster number (1–7) before powering up. Connect the fiber optic cables to the two optical ports, ensuring proper polarity and cable type. Then connect the electrical ModuleBus cable to the I\/O modules. Verify that the power supply meets the 24 V DC requirement (100 mA typical consumption).\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eRegularly inspect fiber optic connections for dirt or damage. Keep the module free of dust to maintain proper cooling. Check the rotary switch position during maintenance to ensure it hasn't been accidentally changed. The TB820V2 is designed for reliable operation within its specified temperature and humidity ranges. Following these simple practices extends its service life and reduces downtime.\u003c\/p\u003e\u003ch2\u003eCompatibility \u0026amp; Integration\u003c\/h2\u003e\u003cp\u003eThe TB820V2 is part of the ABB S800 I\/O family and communicates via the Modulebus protocol. It works as a slave device with parent controllers and PLCs that support the S800 system. It is not compatible with HI controllers. The module supports up to seven clusters on the optical bus, each with up to 12 I\/O modules on the electrical side.\u003c\/p\u003e\u003ch2\u003eSelection Guide\u003c\/h2\u003e\u003cp\u003eBefore purchasing, verify that your system uses the S800 I\/O architecture and that the Modulebus protocol is supported. Check your existing cluster configuration and the number of I\/O modules to ensure the TB820V2 meets your expansion needs. For reliable sourcing and competitive pricing, consider PLC Source PRO for genuine ABB automation parts.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default","offer_id":44447180030051,"sku":"TB820V2","price":246.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/07-KT-97_20ABB__E5_89_AF_E6_9C_AC-c1_a55542f0-287f-4b0b-90f3-a9122d39482a.jpg?v=1785962551","url":"https:\/\/www.plcsourcepro.com\/ar\/products\/abb-tb820v2-cluster-modem-i-o-module-3bse013208r1","provider":"PLC Source PRO","version":"1.0","type":"link"}