{"product_id":"abb-di828-16-channel-120v-ac-dc-digital-input-module-for-s800-i-o","title":"ABB DI828 16-Channel 120V AC\/DC Digital Input Module for S800 I\/O","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe ABB DI828 is a 16-channel 120 V a.c.\/d.c. digital input module engineered for the S800 I\/O system. It delivers reliable signal acquisition for industrial automation, featuring individually isolated channels that enhance noise immunity and system safety. With a compact design and robust construction, the DI828 integrates seamlessly into existing ABB control architectures.\u003c\/p\u003e\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e16 channels for 120 V AC\/DC inputs\u003c\/li\u003e\n\u003cli\u003eIndividually isolated channels for superior protection\u003c\/li\u003e\n\u003cli\u003eInput status indicators for quick diagnostics\u003c\/li\u003e\n\u003cli\u003eSelectable digital filter times (2.5 ms to 20 ms)\u003c\/li\u003e\n\u003cli\u003eVoltage supervision on channels 1 and 16 with group error reporting\u003c\/li\u003e\n\u003cli\u003eCompatible with TU851 mounting terminal unit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle number\u003c\/td\u003e\n\u003ctd\u003e3BSE069054R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal specification\u003c\/td\u003e\n\u003ctd\u003e120 V a.c. \/ d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range \"0\"\u003c\/td\u003e\n\u003ctd\u003e0..30 V a.c., 0..20 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range \"1\"\u003c\/td\u003e\n\u003ctd\u003e77..130 V a.c., 75..130 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e14.2 kΩ (a.c.) \/ 50 kΩ (d.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter times (digital, selectable)\u003c\/td\u003e\n\u003ctd\u003e2.5 ±0.5, 5 ±1, 10 ±2, 20 ±4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency range\u003c\/td\u003e\n\u003ctd\u003e47..63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog filter On\/Off delay\u003c\/td\u003e\n\u003ctd\u003e5 \/ 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum field cable length\u003c\/td\u003e\n\u003ctd\u003e200 m (656 yd) @100 pF\/m for a.c., 600 m (656 yd) for d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric test voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V a.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation\u003c\/td\u003e\n\u003ctd\u003eTyp. 3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption +5 V Modulebus\u003c\/td\u003e\n\u003ctd\u003eTyp. 45 mA, Max 60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption +24 V Modulebus\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 °C (+32 to +131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C (-40 to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e45 x 102 x 119 mm (1.77\" x 4.01\" x 4.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg (0.33 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe DI828 excels in industrial environments where reliable 120V AC\/DC signal monitoring is critical. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMotor control centers (MCC) for status monitoring of contactors and breakers.\u003c\/li\u003e\n\u003cli\u003ePackaging machinery for discrete sensor input collection.\u003c\/li\u003e\n\u003cli\u003eProcess control systems requiring isolated input channels to prevent ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIts individually isolated channels and built-in voltage supervision make it ideal for high-EMI environments.\u003c\/p\u003e\u003ch2\u003eInstallation \u0026amp; Setup\u003c\/h2\u003e\u003cp\u003eMount the DI828 onto a standard S800 I\/O rail using the TU851 mounting terminal unit. Ensure the module is correctly keyed to prevent misinsertion. Connect field wiring to the TU851 terminals, observing the input voltage ranges. For voltage supervision, wire channel 1 (for channels 2-8) or channel 16 (for channels 9-15) to the process voltage source. After power-up, verify the Run LED is lit and the Warning LED is off. No calibration is required.\u003c\/p\u003e\u003ch2\u003eMaintenance \u0026amp; Reliability\u003c\/h2\u003e\u003cp\u003eThis solid-state module requires no routine maintenance. Periodically inspect the front LEDs for fault indications. Keep the module free from dust and moisture; the IP20 rating requires installation in an enclosure. The module's robust design ensures long-term reliability, reducing downtime and maintenance costs.\u003c\/p\u003e\u003ch2\u003eCompatibility \u0026amp; Integration\u003c\/h2\u003e\u003cp\u003eThe DI828 is part of the ABB S800 I\/O family and communicates over the ModuleBus. It is compatible with ABB AC 800M controllers and other S800-compatible systems. The TU851 mounting terminal unit is required for operation.\u003c\/p\u003e\u003ch2\u003eSelection Guide\u003c\/h2\u003e\u003cp\u003eBefore purchasing, verify that your system supports the S800 I\/O series and that the TU851 MTU is available. Ensure the input voltage matches your field signals. For expert advice and guaranteed genuine parts, choose PLC Source PRO as your trusted supplier.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default","offer_id":44443604418659,"sku":"DI828","price":257.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/8635\/0435\/files\/DI828__E5_89_AF_E6_9C_AC-c1.jpg?v=1785929395","url":"https:\/\/www.plcsourcepro.com\/ar\/products\/abb-di828-16-channel-120v-ac-dc-digital-input-module-for-s800-i-o","provider":"PLC Source PRO","version":"1.0","type":"link"}